A comparison of Doppler optical coherence tomography methods

Abstract: We compare, in detail, the phase-resolved color Doppler (PRCD), phase-resolved Doppler variance (PRDV) and intensity-based Doppler variance (IBDV) methods. All the methods are able to quantify flow speed when the flow rate is within a certain range, which is dependent on the adjacent A-line time interval. While PRCD is most sensitive when the flow direction is along the probing beam, PRDV and IBDV can be used to measure the flow when the flow direction is near perpendicular to the probing beam. However, the va… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
128
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
8
1

Relationship

3
6

Authors

Journals

citations
Cited by 106 publications
(129 citation statements)
references
References 41 publications
0
128
1
Order By: Relevance
“…The color-coded angiogram can be superimposed on a gray-scale, cross-sectional, structural OCT image to demonstrate blood flow and structural information simultaneously. Flow projection artifacts are a common problem for existing OCT angiography techniques (3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13). To better distinguish and interpret the blood flow within different layers, a negative filter was used to mask projection artifacts from the larger caliber retinal vessels (24).…”
Section: Discussionmentioning
confidence: 99%
“…The color-coded angiogram can be superimposed on a gray-scale, cross-sectional, structural OCT image to demonstrate blood flow and structural information simultaneously. Flow projection artifacts are a common problem for existing OCT angiography techniques (3)(4)(5)(6)(7)(8)(9)(10)(11)(12)(13). To better distinguish and interpret the blood flow within different layers, a negative filter was used to mask projection artifacts from the larger caliber retinal vessels (24).…”
Section: Discussionmentioning
confidence: 99%
“…112,148,149 For flat vessel beds, signal variance calculations show a linear dependence on the flow. 150 Since most angiographic structures in skin, retina, or the choroicapillaries are parallel to the tissue surface, those methods are currently investigated in detail. Quantitative assessment of the velocity through signal correlation analysis needs, however, fast scan rates in order to avoid complete decorrelation of flow signals.…”
Section: Label-free Optical Angiographymentioning
confidence: 99%
“…11,20 The Doppler variance is only sensitive to motion perpendicular to the OCT beam and can be used to detect the transverse displacement. [21][22][23][24] At the green point, the shear wave from sub-source 1 travels along the blue dashed arrow and its vibration direction is along the blue solid-line arrow, and the shear wave from sub-source 2 travels along the red dashed arrow and its vibration direction is along the red solid-line arrow. Globally, the sum contribution of two vibrations is along the black solid-line arrow, and the shear wave propagates along the black solid-line arrow.…”
mentioning
confidence: 99%