A Comparison of the Conformability of Everolimus-Eluting Bioresorbable Vascular Scaffolds to Metal Platform Coronary Stents

Abstract: Bioresorbable vascular scaffolds have better conformability than conventional MPS. The clinical significance of the observed differences will require further investigation.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
71
0
3

Year Published

2011
2011
2023
2023

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 96 publications
(76 citation statements)
references
References 28 publications
2
71
0
3
Order By: Relevance
“…By multivariate regression analysis, the independent predictors of changes in curvature and angulation were the pretreatment region curvature, the pre-treatment region angulation, and the used device. 18 At 6-or 12-month followup, the anatomical configuration of the arteries treated with the ABSORB BVS allowed restoration of coronary geometry to values close to those measured before implantation. 19 Late vascular remodeling in metallic stent and BVS One possible fate of the dilated but caged lesion is an intra-stent lumen reduction by intra-stent neointimal tissue growth (negative remodeling), even if the cytostatic drug slows down or postpones the phenomenon.…”
Section: Bvs and Vascular Geometrymentioning
confidence: 76%
See 2 more Smart Citations
“…By multivariate regression analysis, the independent predictors of changes in curvature and angulation were the pretreatment region curvature, the pre-treatment region angulation, and the used device. 18 At 6-or 12-month followup, the anatomical configuration of the arteries treated with the ABSORB BVS allowed restoration of coronary geometry to values close to those measured before implantation. 19 Late vascular remodeling in metallic stent and BVS One possible fate of the dilated but caged lesion is an intra-stent lumen reduction by intra-stent neointimal tissue growth (negative remodeling), even if the cytostatic drug slows down or postpones the phenomenon.…”
Section: Bvs and Vascular Geometrymentioning
confidence: 76%
“…This change in vessel biomechanics is also responsible for late strut fractures, that could lead to restenosis and clinical events. 17,18 After metallic stent implantation, the curvature of target vessel is increased by 121% at the entrance and by 100% at the exit of the stent, resulting in local changes in shear stress correlated with the local curvature. The initial superior conformability and flexibility of the ABSORB with respect to metallic stents can, at an early stage, contribute to less change in vessel geometry and biomechanics.…”
Section: Bvs and Vascular Geometrymentioning
confidence: 99%
See 1 more Smart Citation
“…14,15 Furthermore, as recently demonstrated in imaging studies including optical coherence tomography and virtual histology, plaque thinning, morphology changes, and vessel paving, 16,17 although intriguing, should translate into clinical utility when challenging the standard of care for permanent metallic stents.…”
Section: Will Brs Replace Metallic Stents?mentioning
confidence: 97%
“…The curvature value is calculated as 1/radius of the circle in cm −1 . "Angulation" is defined as the angle in degrees that the tip of an intracoronary guidewire would need to reach the distal part of a coronary bend (11).…”
Section: Curvature and Angulationmentioning
confidence: 99%