2006
DOI: 10.1016/j.dental.2005.08.010
|View full text |Cite
|
Sign up to set email alerts
|

A comparison of three different methods for the quantification of the in vitro wear of dental materials

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

5
66
0
3

Year Published

2006
2006
2020
2020

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 79 publications
(74 citation statements)
references
References 13 publications
5
66
0
3
Order By: Relevance
“…Many parameters have been used to evaluate wear resistance, e.g., weight loss 14) , volume loss 14,21) , wear depth [7][8][9]21) , or Ra 15,21,22) . In this study, the parameters Ra and Rz were adopted to evaluate the wear resistance.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Many parameters have been used to evaluate wear resistance, e.g., weight loss 14) , volume loss 14,21) , wear depth [7][8][9]21) , or Ra 15,21,22) . In this study, the parameters Ra and Rz were adopted to evaluate the wear resistance.…”
Section: Discussionmentioning
confidence: 99%
“…Parameter Rz corresponds Rmax in the old Japanese Industrial Standards (JIS B0601:1982); the wear parameters Rmax (Rz) and weight loss were very closely related: one can be predicted from the other 23) . The parameter Ra is also one of the vertical parameter and is frequently used for the quantification of wear facets 21) . As shown Table 4, the Ra of the Cerasmart and Shofu Block HC materials was significantly larger than that of the ceramic block after toothbrush abrasion.…”
Section: Discussionmentioning
confidence: 99%
“…Restorative materials should possess wear properties similar to those of natural teeth. This is essential for the reduction of induced pathological 5 consequences (Heintze et al, 2006). The wear behavior of polished zirconia of the first generation showed only marginal wear rates on enamel antagonists and almost no wear in the zirconia itself (Stawarczyk et al, 2013b).…”
Section: Introductionmentioning
confidence: 99%
“…This new high molecular volume dimethacrylate monomer is the main organic component of the Epiphany TM root canal sealant, which has recently been applied in the clinic. Unfortunately, microleakage due to polymerization shrinkage of Epiphany TM still happens [3][4][5][6]. Based on their investigations of the relationship between polymerization shrinkage and the conversion of double bonds during polymerization of Bis-GMA, Venhoven et al [7] revealed that polymerization shrinkage of monomers is directly influenced by the concentration and conversion of the double bonds.…”
Section: Introductionmentioning
confidence: 99%