2013
DOI: 10.1111/jopr.12083
|View full text |Cite
|
Sign up to set email alerts
|

A Comparison of Two Soldering Techniques on the Misfit of Bar‐Retained Implant‐Supported Overdentures

Abstract: According to our data, the soldering of bars using the torch or furnace oven soldering techniques does not improve the misfit of one-piece cast bars on two implants. The lower misfit was obtained using the porcelain furnace soldering technique.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2018
2018
2020
2020

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(5 citation statements)
references
References 41 publications
0
5
0
Order By: Relevance
“…In the included publications, more than half (27 out of 47 articles) described the implant‐framework misfit with 2D measurements, such as vertical (31 articles) 4,17‐45 and horizontal gaps (4 articles) at the margin, 18,43,44 as well as internal gaps between the mating surfaces (4 articles), 19‐21,46 by stereomicroscope and SEM in different experimental conditions (one‐screw test and definitive‐fit test). Besides, 18 articles demonstrated the implant framework misfit with 3D measurements, 6,18,22,38,42,45,47‐58 including the volumetric discrepancy 58 and spatial deviation in X ‐, Y ‐, and Z ‐axis 6,45,47,48,50,51,54‐56 .…”
Section: Resultsmentioning
confidence: 99%
“…In the included publications, more than half (27 out of 47 articles) described the implant‐framework misfit with 2D measurements, such as vertical (31 articles) 4,17‐45 and horizontal gaps (4 articles) at the margin, 18,43,44 as well as internal gaps between the mating surfaces (4 articles), 19‐21,46 by stereomicroscope and SEM in different experimental conditions (one‐screw test and definitive‐fit test). Besides, 18 articles demonstrated the implant framework misfit with 3D measurements, 6,18,22,38,42,45,47‐58 including the volumetric discrepancy 58 and spatial deviation in X ‐, Y ‐, and Z ‐axis 6,45,47,48,50,51,54‐56 .…”
Section: Resultsmentioning
confidence: 99%
“…These data agree with other studies. 3,13,28,38 The misfit improvement in the majority of the frameworks after sectioning and welding may be related to the fact that this technique enables a reduction of distortions generated by the one-piece casting technique, which is caused by clinical and laboratorial steps, such as waxing, coating, and impression. 24,39,40 Most studies that observed favorable differences regarding the welding technique were conducted using the laser welding technique.…”
Section: Discussionmentioning
confidence: 99%
“…After a detailed reading of the titles and abstracts and application of the eligibility and exclusion criteria, a total of 27 articles were selected for reading. After reading the articles, 15 articles 1,4,13,10,27,28,29,30,31,32,33,34,35,36,37 were excluded due to the reasons listed in Table 1. Thus, 11 articles were included to analyze the results 2,[5][6][7]11,12,17,18,23,24,25 , and 7 studies were selected for a quantitative analysis.…”
Section: Search Strategymentioning
confidence: 99%
“…The implant-supported bar overdenture is an effective prosthetic treatment for edentulous jaws, particularly when the implants are misaligned [ 1 , 2 ]. Accuracy of a bar framework is essential for longevity of the treatment [ 2 , 3 ]. Framework deformation during the fabrication procedure leads to inaccuracies and misfit of the frameworks [ 4 ].…”
Section: Introductionmentioning
confidence: 99%
“…Nonetheless, when the framework is of a large size, the risk of framework misfit is considerably great due to unpredictable contraction of the alloy [ 6 ]. To avoid compromising the fit accuracy of the framework, the framework can be segmented and reconnected [ 2 , 10 ]. However, the soldering adjustment decreases the homogeneity of the material and causes new errors in adaptation [ 11 ].…”
Section: Introductionmentioning
confidence: 99%