2018
DOI: 10.1002/aelm.201800137
|View full text |Cite
|
Sign up to set email alerts
|

A Composite Elastic Conductor with High Dynamic Stability Based on 3D‐Calabash Bunch Conductive Network Structure for Wearable Devices

Abstract: As an indispensable basic component of wearable devices, the composite elastic conductor is widely used for elastic electrode and elastic wire. The ideal elastic conductor is expected to have high conductivity and stretchability, and maintain the resistance constant during stretching. However, it's difficult for the current composite elastic conductors filling solid conductive materials. Here, a composite elastic conductor filling liquid‐metal alloy is reported. Highly conductive and freely deformable liquid‐m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
49
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 63 publications
(50 citation statements)
references
References 85 publications
0
49
1
Order By: Relevance
“…Firstly, the Joule heating performance of six MWEs (MWE 32 wt%, MWE 35 wt%, MWE 38 wt%, MWE 38 wt%-H (1) , MWE 38 wt%-H (2) , and MWE 38 wt%-H (3) ) at 1, 2, 3, and 4 V are tested ( Figure S9, Supporting Information). The test length of the MWEs as a heater is 30 mm, the duration of the applied voltage is 100 s, and the maximum monitored temperature of the FLIR C3 is 180 °C.…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Firstly, the Joule heating performance of six MWEs (MWE 32 wt%, MWE 35 wt%, MWE 38 wt%, MWE 38 wt%-H (1) , MWE 38 wt%-H (2) , and MWE 38 wt%-H (3) ) at 1, 2, 3, and 4 V are tested ( Figure S9, Supporting Information). The test length of the MWEs as a heater is 30 mm, the duration of the applied voltage is 100 s, and the maximum monitored temperature of the FLIR C3 is 180 °C.…”
Section: Resultsmentioning
confidence: 99%
“…Firstly, the Joule heating performance of six MWEs (MWE 32 wt%, MWE 35 wt%, MWE 38 wt%, MWE 38 wt%-H (1) , MWE 38 wt%-H (2) , and MWE 38 wt%-H (3) ) at 1, 2, 3, and 4 V are tested ( Figure S9, Supporting Information). The actual heating areas of MWE 38 wt%, MWE 38 wt%-H (1) , MWE 38 wt%-H (2) , and MWE 38 wt%-H (3) are 3, 0.84, 1.39, and 2.3 cm 2 , respectively. The effect of the SC of Ag FDs in the conductive layer on the MWE heating performance is studied and shown in Figure 6a,c (I-III).…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations