A dosimetric comparison of Xoft Axxent Electronic Brachytherapy and iridium-192 high-dose-rate brachytherapy in the treatment of endometrial cancer

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
39
0

Year Published

2011
2011
2019
2019

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 35 publications
(40 citation statements)
references
References 7 publications
1
39
0
Order By: Relevance
“…Overall, it has been shown that Xoft miniature x-ray source can produce comparable dose distribution for intracavitory brachytherapy treatment compared to 192 Ir source [26][27][28] . One major concern is the relatively more rapid dose fall off with distance in tissue compared to 192 Ir source, which results in a higher surface dose near the MammoSite balloon applicator for APBI treatment or the Vaginal cylinder applicator for endometrial treatment.…”
Section: Comparison With Isotope-based Hdr Brachytherapymentioning
confidence: 99%
“…Overall, it has been shown that Xoft miniature x-ray source can produce comparable dose distribution for intracavitory brachytherapy treatment compared to 192 Ir source [26][27][28] . One major concern is the relatively more rapid dose fall off with distance in tissue compared to 192 Ir source, which results in a higher surface dose near the MammoSite balloon applicator for APBI treatment or the Vaginal cylinder applicator for endometrial treatment.…”
Section: Comparison With Isotope-based Hdr Brachytherapymentioning
confidence: 99%
“…The results were in good agreement and consistent with what has been published in the literature for the Xoft-EBS source. 7,8 OARs including rectum, bladder, sigmoid and small bowel were all individually contoured. The Foley catheter balloon with the contrast media was also contoured to represent the bladder.…”
Section: Methodsmentioning
confidence: 99%
“…7 This electronic brachytherapy system has been investigated by numerous authors for brachytherapy applications such as accelerated partial breast irradiation, surface treatments for skin cancers and endometrial cancer brachytherapy treatments but not for tandem and ovoids (T&O) applicators. [7][8][9][10] The objective of this study was to evaluate the dosimetry of T&O treatment plans generated using the Axxent-Xoft EBS. These plans were then compared with plans generated with the 192 Ir and 60 Co HDR radioactive sources.…”
Section: Advances In Knowledgementioning
confidence: 99%
“…Conversely, doses to surrounding organs at risk are lower, because of the relatively rapid dose fall off. 25,26 Dosimetric characteristics have also been described for endometrial, 27 surface 28 and endocavitary applicators.…”
Section: Clinical Systemsmentioning
confidence: 99%