2002
DOI: 10.1016/s0304-8853(02)00655-8
|View full text |Cite
|
Sign up to set email alerts
|

A double-coated magnetite-based magnetic fluid evaluation by cytometry and genetic tests

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

2
25
0

Year Published

2006
2006
2022
2022

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 33 publications
(27 citation statements)
references
References 8 publications
2
25
0
Order By: Relevance
“…Significant differences were not observed in the most abundant peritoneal cell populations (macrophages and lymphocytes). However, some fluctuations in peritoneal cell populations related to the inflammatory response (neutrophils and eosinophils) 19,[30][31][32] were detected until 7 days, even after just one single injection of MAN, as observed previously. These fluctuations in peritoneal cell viability may be associated with the particulate state of the intraperitoneally administered MNPs and the consequent responses of neutrophil and eosinophil populations.…”
Section: Discussionsupporting
confidence: 83%
See 2 more Smart Citations
“…Significant differences were not observed in the most abundant peritoneal cell populations (macrophages and lymphocytes). However, some fluctuations in peritoneal cell populations related to the inflammatory response (neutrophils and eosinophils) 19,[30][31][32] were detected until 7 days, even after just one single injection of MAN, as observed previously. These fluctuations in peritoneal cell viability may be associated with the particulate state of the intraperitoneally administered MNPs and the consequent responses of neutrophil and eosinophil populations.…”
Section: Discussionsupporting
confidence: 83%
“…Although micronuclei development may be associated with reactive oxygen species (ROS) induced by iron excess, 23,33 in the present study, the MN assay showed no MAN effect on cell division or genotoxicity, differently from other samples based on magnetic nanoparticles. 19,20,32 Also, the % PCE indicated that the MAN sample was not cytotoxic to the erythrocytic lineage in bone marrow.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Most widely used biocompatible magnetic fluid is magnetite (Fe 3 O 4 ) based [4]. Several surfactant-and polymer-based coating materials like citrate, polyaspertic acid, dextran have been tested for biocompatibility [4][5][6][7][8]. Dextran coating has been used mostly because of its biocompatibility [4,9].…”
mentioning
confidence: 99%
“…Iron deposition within the cells was detected by characteristic blue color of prussian blue. For this study, cells were first grown on cover slips for 24 h after which they were exposed to LMN and DMN at different concentrations (0.2 and 0.4 mg/ml of cell culture suspension) for 24 and 48 h. The cover slips were then immersed in a mixture containing equal volume of 20% aqueous solution of HCl and 10% aqueous solution of potassium ferrocyanide [K 4 Fe(CN) 6 , 3H 2 O] for 20 min and counterstaining was done by nuclear fast red for 5 min. Photographs were taken in bright field mode using Olympus BX 51 microscope.…”
mentioning