A Dual-Chamber, Thick-Walled Cardiac Phantom for Use in Cardiac Motion and Deformation Imaging by Ultrasound

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
22
0

Year Published

2012
2012
2021
2021

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 38 publications
(22 citation statements)
references
References 28 publications
0
22
0
Order By: Relevance
“…As an alternative to simulated data, 3D US strain algorithms can be validated on physical phantoms, where motion and deformations can be mechanically controlled [19]. In phantoms, ground truth deformation typically relies on sonomicrometry.…”
Section: A Validation Of 3d Us Strain Algorithmsmentioning
confidence: 99%
“…As an alternative to simulated data, 3D US strain algorithms can be validated on physical phantoms, where motion and deformations can be mechanically controlled [19]. In phantoms, ground truth deformation typically relies on sonomicrometry.…”
Section: A Validation Of 3d Us Strain Algorithmsmentioning
confidence: 99%
“…Then the mold was placed in a freezer at À25 AE 0.5 8C for 35 h and then thawed for approximately 40 h to the room temperature [12,23]. This process was initially introduced by Surry et al [23] and next applied by Langeland et al [10] and by Leśniak-Plewińska et al [11].…”
Section: Ultrasound Model Of the Left Ventriclementioning
confidence: 99%
“…The dual-chamber ventricular phantom was used for ultrasonic examination of the left ventricle strains during an in vitro experiment [11]. The authors focused on testing of the physiological LV strains by imitating more ellipsoidal shape of the ventricle and on the dependence of left ventricle functions and its ''interconnection'' with the right ventricle.…”
Section: Introductionmentioning
confidence: 99%
“…While porcine models generally perform well for testing hemodynamics; unfortunately, this is not the case for the LV morphology. The trabeculae carneae as well as the papillary muscles need to be replicated more accurately than current existing heart phantoms allow (20)(21)(22)(23)(24), which shows the need for the use of an advanced additive manufacturing technique (25)(26)(27). In the human LV, the ultrasonic beam encounters complex reflection and refraction patterns at the intra-ventricular surface.…”
Section: Introductionmentioning
confidence: 99%