2013 IEEE International Solid-State Circuits Conference Digest of Technical Papers 2013
DOI: 10.1109/isscc.2013.6487737
|View full text |Cite
|
Sign up to set email alerts
|

A fully integrated 8-channel closed-loop neural-prosthetic SoC for real-time epileptic seizure control

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 5 publications
0
4
0
Order By: Relevance
“…Several stimulation artifact cancelation techniques have been reported previously. The blanking technique and digital signal processing (Erez et al, 2010) have been used to cancel the artifact (Olsson et al, 2005;Venkatraman et al, 2009;Kent and Grill, 2011;Myers et al, 2011;Zoladz et al, 2012;Wei-Ming et al, 2013;Yi et al, 2013;Bozorgzadeh et al, 2014;Elyahoodayan et al, 2019). In the blanking technique, the RFE is switched off or disabled (input is shorted to ground) during the stimulation period and turned on after the stimulation is completed to continue the recording.…”
Section: Key Issues In Neural Recording and Stimulation Circuits Stimulation Induced Artifact In The Closed-loop Systemmentioning
confidence: 99%
“…Several stimulation artifact cancelation techniques have been reported previously. The blanking technique and digital signal processing (Erez et al, 2010) have been used to cancel the artifact (Olsson et al, 2005;Venkatraman et al, 2009;Kent and Grill, 2011;Myers et al, 2011;Zoladz et al, 2012;Wei-Ming et al, 2013;Yi et al, 2013;Bozorgzadeh et al, 2014;Elyahoodayan et al, 2019). In the blanking technique, the RFE is switched off or disabled (input is shorted to ground) during the stimulation period and turned on after the stimulation is completed to continue the recording.…”
Section: Key Issues In Neural Recording and Stimulation Circuits Stimulation Induced Artifact In The Closed-loop Systemmentioning
confidence: 99%
“…Up-conversion transmitters are transmitters in any frequency band, which utilize a mixer topology to up-convert the frequency content of the base band data signal. This technique is rarely used [104][105][106] because of its many drawbacks, albeit it has some advantage as well. The device needs two antennas, of which one is used for powering and one for data communication (In principle a single multimodal antenna could be used).…”
Section: B Remotely Powered Systemsmentioning
confidence: 99%
“…Functionally, neural stimulation is used to activate the prosthesis and wake up the sensory function [6], while neural recording can sense nerve signals or complete the evaluation of stimulation effect [7][8][9]. Combining neural stimulator and neural recorder, the closed-loop controlled simultaneous neural recording and stimulation system is formed to recover the basic functions of the injured individuals [10][11][12][13][14][15][16], such as the system for epileptic seizure detection and suppression [17,18].…”
Section: Introductionmentioning
confidence: 99%