2018
DOI: 10.1002/mrm.27524
|View full text |Cite
|
Sign up to set email alerts
|

A functional form for a representative individual arterial input function measured from a population using high temporal resolution DCE MRI

Abstract: Purpose To measure the arterial input function (AIF), an essential component of tracer kinetic analysis, in a population of patients using an optimized dynamic contrast‐enhanced (DCE) imaging sequence and to estimate inter‐ and intrapatient variability. From these data, a representative AIF that may be used for realistic simulation studies can be extracted. Methods Thirty‐nine female patients were imaged on multiple visits before and during a course of neoadjuvant chemotherapy for breast cancer. A total of 97 … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
53
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 24 publications
(53 citation statements)
references
References 30 publications
0
53
0
Order By: Relevance
“…This difference could be due to the literature‐based AIF being measured from the abdomen instead of the brain or due to variations in injection protocol. Although the preliminary results presented here are promising, it should be noted that there are many literature‐based AIFs and their tail concentrations are not exactly equal . Determining the cause for this variation requires further study.…”
Section: Discussionmentioning
confidence: 76%
See 4 more Smart Citations
“…This difference could be due to the literature‐based AIF being measured from the abdomen instead of the brain or due to variations in injection protocol. Although the preliminary results presented here are promising, it should be noted that there are many literature‐based AIFs and their tail concentrations are not exactly equal . Determining the cause for this variation requires further study.…”
Section: Discussionmentioning
confidence: 76%
“…The inflow effect can lead to a bias of roughly 40% but this can be corrected with additional measurements, or the effect can be minimized by changing the slice orientation or by optimal selection of the AIF voxel . The impact of partial volume effects is difficult to quantify because they have a non‐linear effect on the AIF shape and the severity depends on the acquired spatial resolution. Since RRIFT is viable at slower temporal resolutions, the extra scan time could be used to improve volume coverage, spatial resolution, and noise.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations