2013
DOI: 10.1007/s40313-013-0094-2
|View full text |Cite
|
Sign up to set email alerts
|

A Fuzzy Control Strategy for a Diesel Generating Set under Stand-alone and Grid-Connected Operations

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
1
0
2

Year Published

2016
2016
2024
2024

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 27 publications
0
1
0
2
Order By: Relevance
“…Additionally, without non-dispatchable energy generation (e.g., PV-or wind-based DERs), it is not trivial for MGs to reach a desired level of operational independence from the upstream grid and other market players, since more power would need to be imported. An exception to that is, for instance, a particular scenario in which diesel generators exist and take the role of being the main suppliers of energy to meet the MG's internal demand [61]. Consequently, the existence of non-dispatchable DERs should be incorporated into any generalized management framework targeting transactive control over MGs.…”
Section: Fundamental Concepts For Implementing a Flexible Mg Operationmentioning
confidence: 99%
“…Additionally, without non-dispatchable energy generation (e.g., PV-or wind-based DERs), it is not trivial for MGs to reach a desired level of operational independence from the upstream grid and other market players, since more power would need to be imported. An exception to that is, for instance, a particular scenario in which diesel generators exist and take the role of being the main suppliers of energy to meet the MG's internal demand [61]. Consequently, the existence of non-dispatchable DERs should be incorporated into any generalized management framework targeting transactive control over MGs.…”
Section: Fundamental Concepts For Implementing a Flexible Mg Operationmentioning
confidence: 99%
“…No entanto, a prática adotada pela indústria consiste em considerar puramente o controle de potência ativa na operação paralela do geradorà rede. Nesta configuraçãoé comumente aplicado um controlador do tipo PID (Reis et al, 2014…”
Section: Sistemas De Regulação De Velocidadeunclassified
“…A malha de controle de tensão recebe a tensão medida nos terminais do gerador síncrono (E) e o sinal de referência de tensão (E ref ) e atua no gerador através da excitatriz e do enrolamento de campo. A GD opera com a malha de controle de tensão e frequência se estiver no modo isolado, ou seja, sem a presença da RD (REIS et al, 2014).…”
Section: Geração Distribuída Baseada Em Máquina Síncronaunclassified