2011
DOI: 10.1016/j.renene.2011.03.038
|View full text |Cite
|
Sign up to set email alerts
|

A hierarchical methodology for the mesoscale assessment of building integrated roof solar energy systems

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
33
0
3

Year Published

2012
2012
2022
2022

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 61 publications
(37 citation statements)
references
References 10 publications
1
33
0
3
Order By: Relevance
“…East-and west-facing roofs also had potential, but a north-facing roof did not have potential. The result is similar to previous studies, such as those conducted by Jo et al [25] and Ordonez et al [26]. The electricity that can be generated in each year was calculated from the watt-peak rating of the module, sunlight hours per day, and the number of rain-free days in a year.…”
Section: Resultssupporting
confidence: 85%
See 1 more Smart Citation
“…East-and west-facing roofs also had potential, but a north-facing roof did not have potential. The result is similar to previous studies, such as those conducted by Jo et al [25] and Ordonez et al [26]. The electricity that can be generated in each year was calculated from the watt-peak rating of the module, sunlight hours per day, and the number of rain-free days in a year.…”
Section: Resultssupporting
confidence: 85%
“…Izquierdo et al [24] studied the influence of hourly shadows on monthly values via geometrical calculations with digital terrain models; the results show that the shadowing coefficient varies from 0.33 to 0.52, depending on the municipality type (as a function of population and building densities) in Spain. Jo et al [25] utilized Google SketchUp for shadow analysis, a 3D computer modeling program able to cast shadows based on the longitude and latitude of the site. The result of the study (which included 932 buildings) was that about 30% of the total rooftop area of unshaded, predominately flat, roofs were suitable for PV applications.…”
Section: Introductionmentioning
confidence: 99%
“…The researchers do not discuss how many rooftops are ground-truthed for accuracy. The Chandler, Arizona, study (Jo and Otanicar 2011) includes a visual ground inspection of 150 of the 932 analyzed buildings to validate rooftop obstructions and area estimates with the satellite imagery used in the analysis.…”
Section: Validation Of Resultsmentioning
confidence: 99%
“…The Chandler study (Jo and Otanicar 2011) assesses imagery for brightness value to determine the potential areas of shadow and obstructions on commercial and government rooftops in a 4-square mile area of the city. The lengths of shadows are estimated in detail using Google SketchUp by casting simulated shadows on a 3-D building model.…”
Section: Gis-based Methodsmentioning
confidence: 99%
“…Bergamasco and Asinari (2011) proposed a method to compute the available roof surface for integrated solar (PV) installations through the analysis of shadow zones, space, brightness and suitability for PV installation. Jo and Otanicar (2011) analysed the patterns of shadow cast and their effects on the rooftop in order to estimate the available rooftop area for PV installation. A number of researchers have also published works and approaches that exploit the derived information from shadow analysis.…”
Section: The Importance Of Shadow Detection In Urban Environmentsmentioning
confidence: 99%