2019
DOI: 10.1063/1.5054116
|View full text |Cite
|
Sign up to set email alerts
|

A high resolution extreme ultraviolet spectrometer system optimized for harmonic spectroscopy and XUV beam analysis

Abstract: Time-and angle-resolved photoemission spectroscopy of solids in the extreme ultraviolet at 500 kHz repetition rate Review of Scientific Instruments 90, 023104 (2019);

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 14 publications
(5 citation statements)
references
References 23 publications
1
4
0
Order By: Relevance
“…Based on the above arguments, it is reasonable to consider the two-photon ionization process which leads to the final states f 1/2 and f 3/2 only. The energy of the subsequent fluorescent photons emitted by a decay of these two states differs by about 0.25 eV, which is well within experimentally resolvable limits [29]. Therefore, these photons can be easily distinguished and their density matrix is given by…”
supporting
confidence: 65%
See 1 more Smart Citation
“…Based on the above arguments, it is reasonable to consider the two-photon ionization process which leads to the final states f 1/2 and f 3/2 only. The energy of the subsequent fluorescent photons emitted by a decay of these two states differs by about 0.25 eV, which is well within experimentally resolvable limits [29]. Therefore, these photons can be easily distinguished and their density matrix is given by…”
supporting
confidence: 65%
“…Moreover, the subsequent fluorescent photon carries energy E 1s 2 2s 2 2p 5 3s4s − E 1s 2 2s 2 2p 6 4s ≥ 52.26 eV [27], depending on coupling of 2p 5 3s4s electrons. It is therefore clear, that in comparison to ≈ 50 eV produced by the dominant channels, one can filter out the photons arising from the shake-up decay channel by the photon detector [29].…”
mentioning
confidence: 99%
“…The divergent EUV radiation is focused into another vacuum chamber by a toroidal mirror. At the focus of the EUV beam, a flat EUV mirror can be moved into the beam to steer it into a high resolution EUV spectrometer [42], which served as an online diagnostic for the produced HHG radiation. Without the mirror, the divergent beam propagated to another pumping stage into the detection chamber consisting of the cryogenic cooling unit and the actual SNSPD, which was exposed to the EUV radiation without any further filter foils.…”
Section: Setupmentioning
confidence: 99%
“…Precise positioning of the sample is realized by motorized positioners. The reflected radiation is characterized spectrally by an XUV spectrometer [28][29][30] in case of a broad bandwidth source (spectrometer-based XCT). Alternatively, when spectrally tunable monochromatic radiation is used, the reflectivity can be measured by a photodiode while sweeping the wavelength (swept-source XCT) [18].…”
Section: A Common-path Interferometric Apparatus For Xctmentioning
confidence: 99%