2016
DOI: 10.1039/c6nj01544a
|View full text |Cite
|
Sign up to set email alerts
|

A highly selective fluorescent sensor for the detection of Al3+ and CN in aqueous solution: biological applications and DFT calculations

Abstract: A new turn-on fluorescent chemosensor 1 was developed to detect both Al3+ and CN− and used for practical and biological applications.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 39 publications
(14 citation statements)
references
References 82 publications
0
14
0
Order By: Relevance
“…The value of the binding constant was calculated as 3.9 • 10 3 M -1 which was within the range of those (10 3 -10 9 M -1 ) previously reported Al 3+ sensors. 41 In addition, the linear plot also proved the 1:1 complexation behavior of SK-1 to Al 3+ . Because, if a 1:1 metal-probe complex is formed between receptor and metal ions, Benesi-Hildebrand plot should be linear.…”
Section: Binding Studiesmentioning
confidence: 70%
“…The value of the binding constant was calculated as 3.9 • 10 3 M -1 which was within the range of those (10 3 -10 9 M -1 ) previously reported Al 3+ sensors. 41 In addition, the linear plot also proved the 1:1 complexation behavior of SK-1 to Al 3+ . Because, if a 1:1 metal-probe complex is formed between receptor and metal ions, Benesi-Hildebrand plot should be linear.…”
Section: Binding Studiesmentioning
confidence: 70%
“…The pH dependence of IH-Sal -Zn 2+ for biological application was tested with various pH values (6–9, Figure S8 ). While there was no fluorescence emission at pH 6, IH-Sal -Zn 2+ showed a remarkable fluorescence response between pH 7 and 9, indicating that IH-Sal can clearly recognize Zn 2+ by the fluorescence application within the environmental pH range [ 68 ]. Based on the result of the pH dependence, fluorescence imaging of zebrafish was performed to widen the biological application.…”
Section: Resultsmentioning
confidence: 99%
“…A hypsochromic shi to 477 nm is observed with a signicant increase of f b (0.0237) for Ad1 (S 0 / S 1 transition, HOMO / LUMO, HOMO / LUMO + 1), suggesting formation of rigid Ad1. 49 Another HOMO / LUMO transition along with HOMO / LUMO + 1 have been observed for S 0 / S 2 with f b ¼ 0.0095. The HOMO-LUMO energy gap in L2 is 0.11953 eV while it is 0.110807 eV in Ad2 (Fig.…”
Section: Density Functional Theoretical (Dft) Studiesmentioning
confidence: 88%