1990
DOI: 10.1007/bf00331409
|View full text |Cite
|
Sign up to set email alerts
|

A highly sensitive high-performance liquid chromatographic procedure for the determination of isocyanates in air

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0
1

Year Published

1995
1995
2024
2024

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(4 citation statements)
references
References 13 publications
0
3
0
1
Order By: Relevance
“…The release of monomeric MDI, even during the production process, is very slight. Through highly sensitive analytical methods at the workplace, SCHMIDTKE and SEIFERT [98] were able to prove the existence of MDI concentrations at a maximum of 2500 ng/m 3 . With freshly prepared wood-based panels, no subsequent emission of MDI could be proven [99].…”
Section: Emission Of Adhesives During Productionmentioning
confidence: 98%
“…The release of monomeric MDI, even during the production process, is very slight. Through highly sensitive analytical methods at the workplace, SCHMIDTKE and SEIFERT [98] were able to prove the existence of MDI concentrations at a maximum of 2500 ng/m 3 . With freshly prepared wood-based panels, no subsequent emission of MDI could be proven [99].…”
Section: Emission Of Adhesives During Productionmentioning
confidence: 98%
“…Because legislation in many countries nowadays requires estimation of TRIG and, as for most industrially used oligomeric isocyanates, there are no standards available, most methods cannot be used for quantification of total isocyanate groups. In MDHS 25/3 these oligomers are quantified by use of an electrochemical detector, which oxidizes the methoxy group on the 2-MP reagent, thus giving a signal independent of the analyte backbone [75,112,113]. Quantification of oligomeric isocyanates can, therefore, be based on the use of the corresponding monomer, e.g.…”
Section: -(N-methylaminomethyl)anthracene (Mama)mentioning
confidence: 99%
“…Evaporation of the solvent during sampling is a source of major concern. Most personal sampling methods therefore rely on use of solvent-free systems, for example impregnated filters [97,107,118,119,162,164] or reagent-coated adsorbent tubes [113,147]. Occasionally, however, especially in fast-curing environments, use of impingers may be necessary to guarantee complete derivatization.…”
Section: Generalmentioning
confidence: 99%
“…Bei der Simulation einer Wohnraumsituation mit mindestens drei Monate alten PMDI-gebundenen Spanplatten konnte bei einer Nachweisgrenze von 0,1 µg/m 3 keine MDI-Emission festgestellt werden (Kehl 1990). Messungen an frisch gepreßten Spanplatten in einer 20 Liter Prüfkammer mit einer Belegung von 5 m 2 /m 3 ergaben eine MDI Konzentration von 0,01 µg/m 3 (Schmidtke, Seifert 1990), während bei zwei Stunden alten Platten auch bei erhöhten Temperaturen (60 °C) keine MDI-Abgabe festgestellt wurde (Marutzky, Menzel 1985). Von baubiologischer Seite jedoch werden immer wieder Vermutungen geäußert, daß Emissionen aus ungebundenen Isocyanaten aus Platten abgegeben und eine Gesundheitsgefahr für die Raumbenutzer darstellen (z.B.…”
unclassified