Background
To analyze in a prospective study the long-term safety and efficacy of 3-dimensional conformal radiotherapy (3D-CRT) to deliver accelerated partial breast irradiation (APBI) for Japanese women with early breast cancer.
Methods
Breast cancer patients with pathological tumor size ≤ 3 cm, age ≥ 20 years, lumpectomy with at least a 5 mm margin, and ≤ 3 positive axillary nodes were eligible. APBI was delivered by 3D-CRT at a dose of 38.5 Gy in 10 fractions over 10 days. The primary endpoints were the frequency and severity of acute and late radiation toxicities, and secondary endpoints were local control, survival, and cosmesis. The sample size was determined based on the incidence of ≥ grade 3 acute and late radiation toxicities, which required 71 enrollments.
Results
Between 2008 and 2010, 73 patients enrolled in this trial. Twelve patients (16%) had 1–3 lymph node metastases. At a median follow-up of 12.6 years (range: 2.7–13.9 years), there were no cases of grade ≥ 3 acute or late toxicity. There were 4 ipsilateral breast tumor recurrence (IBTR) events: 12-year IBTR incidence was 4.4%. The difference in the incidence of IBTR between node-negative and node-positive patients was marginal (1.9% vs. 16.7%, p = 0.055). The majority of patients (94.4% at 2 years, 89.3% at 10 years after enrollment) had excellent/good cosmesis.
Conclusions
APBI delivered with 3D-CRT is a feasible treatment option for Asian females, but it was indicated that node-positive status might increase IBTR risk.