2003
DOI: 10.1016/s0960-1481(02)00253-7
|View full text |Cite
|
Sign up to set email alerts
|

A mathematical model of thermal performance of a solar air heater with slats

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
14
0
1

Year Published

2005
2005
2020
2020

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 65 publications
(16 citation statements)
references
References 11 publications
1
14
0
1
Order By: Relevance
“…When comparing these efficiencies to the ones of Ammari [6], performed on similar SAHs, similar results can also be observed: for an irradiation of about 850 W/m 2 and 180 m 3 /h airflow, the average efficiency exceeds 0.7. Efficiencies obtained here are better than the ones achieved by Budea [1] from a similar system, which scarcely reach 45% for irradiations of about 850 W/m 2 , although no specific information on the operating airflows is given in this case.…”
Section: Discussionsupporting
confidence: 71%
See 1 more Smart Citation
“…When comparing these efficiencies to the ones of Ammari [6], performed on similar SAHs, similar results can also be observed: for an irradiation of about 850 W/m 2 and 180 m 3 /h airflow, the average efficiency exceeds 0.7. Efficiencies obtained here are better than the ones achieved by Budea [1] from a similar system, which scarcely reach 45% for irradiations of about 850 W/m 2 , although no specific information on the operating airflows is given in this case.…”
Section: Discussionsupporting
confidence: 71%
“…Concerning solar thermal energy technologies, the use of air as the working fluid has some advantages: no risk of freezing in winter, no damage due to overheating in summer, no adverse effect of small leakage, corrosion is less critical, and the installation is simpler due to the unneeded additional heat exchanger for the final application [5,6]. The main disadvantages are, nonetheless, its lower density and lower thermal capacity, as well as its lower heat conductivity [7][8][9].…”
Section: Introductionmentioning
confidence: 99%
“…We find ''louvered'' metal sheets [43][44][45][46][47][48], finned metal sheets [32,47,49,50,[56][57][58] until the arrival of the porous absorber. These modifications are shown in Fig.…”
Section: Energy Transfer To the Heat-transfer Fluidmentioning
confidence: 99%
“…The energy conservation equation over the inclined part of the rib is considered as a classical fin case (Ammari, 2003). The node T o is taken as the average temperature of this inclined wall.…”
Section: The Inclined Part Of the Ribmentioning
confidence: 99%
“…The convective heat exchange coefficient between the cells surface and the ambient air can be obtained by the formula (Ammari, 2003):…”
Section: Heat Balance N°2mentioning
confidence: 99%