2014
DOI: 10.1016/j.brachy.2014.07.004
|View full text |Cite
|
Sign up to set email alerts
|

A medical image-based graphical platform—Features, applications and relevance for brachytherapy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
16
0
2

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 19 publications
(18 citation statements)
references
References 18 publications
0
16
0
2
Order By: Relevance
“…MC simulations were performed with MCNP6 (Monte Carlo n-Particle, version 1.0 [30]), which is integrated in the auxiliary software AMIGOBrachy [28]. A phase space source was used for calculation, validated in a previous study [31].…”
Section: Simulationsmentioning
confidence: 99%
See 3 more Smart Citations
“…MC simulations were performed with MCNP6 (Monte Carlo n-Particle, version 1.0 [30]), which is integrated in the auxiliary software AMIGOBrachy [28]. A phase space source was used for calculation, validated in a previous study [31].…”
Section: Simulationsmentioning
confidence: 99%
“…For assessing dose transported in medium and scored in water (D w,m ) or scored in the medium itself (D m,m ), MC simulations were performed on a heterogeneous patient model (TG-186) based on the CT geometry. The CT images were segmented using auxiliary software, AMIGOBrachy [28], to create voxel geometries consisting of 5 tissues (lung (ρ = 0.26 g/cm 3 ), mean adipose tissue (ρ = 0.95 g/cm 3 ), mean male soft tissue (ρ = 1.03 g/cm 3 ), mean female soft tissue (ρ = 1.02 g/cm 3 ), liver (ρ = 1.06 g/cm 3 ), and cortical bone (ρ = 1.92 g/cm 3 )), with compositions and densities recommended by TG-186 [1], and air (ρ = 0.0012 g/cm 3 ). The segmentation was performed by assigning homogeneous densities corresponding to the tissues specified above to fixed Hounsfield Unit (HU) ranges (see Table 2).…”
Section: Simulationsmentioning
confidence: 99%
See 2 more Smart Citations
“…Commissioning resources available on the Registry are presently limited to an initial set of four generic test plans for HDR 192 Ir brachytherapy; however, these will be augmented with clinical site-specific HDR 192 Ir test plans and eventually extended to include 125 I brachytherapy. The peer-reviewed literature also offers guidance and resources to aid in MBDCA commissioning [30, 31, 32, 33, 34]. …”
Section: Commercial Treatment Planning Systems Incorporating Model-bamentioning