A Method for Automatic Identification of Reliable Heart Rates Calculated from ECG and PPG Waveforms

Abstract: This method provides a robust approach for automatically assessing the reliability of large quantities of heart rate data and the waveforms from which they are derived.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
70
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 93 publications
(71 citation statements)
references
References 12 publications
1
70
0
Order By: Relevance
“…20,24,25 Here, we used the same validated methodology, summarized as follows: For each vital-sign value, reliable data were identified by automated algorithms that rated each datum on an integer scale from least to most reliable. 24,26,27 HR and RR reliability algorithms involved analysis of ECG and IP waveforms, respectively. 26,27 Briefly, when the waveforms were clean with rhythmic, consistent beats or breaths, the corresponding rates tended to be rated as reliable.…”
Section: Vital-sign Data Processingmentioning
confidence: 99%
See 1 more Smart Citation
“…20,24,25 Here, we used the same validated methodology, summarized as follows: For each vital-sign value, reliable data were identified by automated algorithms that rated each datum on an integer scale from least to most reliable. 24,26,27 HR and RR reliability algorithms involved analysis of ECG and IP waveforms, respectively. 26,27 Briefly, when the waveforms were clean with rhythmic, consistent beats or breaths, the corresponding rates tended to be rated as reliable.…”
Section: Vital-sign Data Processingmentioning
confidence: 99%
“…24,26,27 HR and RR reliability algorithms involved analysis of ECG and IP waveforms, respectively. 26,27 Briefly, when the waveforms were clean with rhythmic, consistent beats or breaths, the corresponding rates tended to be rated as reliable. Conversely, when the waveforms were noisy with irregular, heterogeneous beats or breaths, the rates were rated as unreliable.…”
Section: Vital-sign Data Processingmentioning
confidence: 99%
“…11 shows other types of distorted heartbeat signals and the results of their conversion with Eq. (14). Fig.…”
Section: Resultsmentioning
confidence: 99%
“…To accomplish this, our ring sensor needs to be more complete and reliable in real dynamic environments. Therefore, we will attempt to improve our system with regard to extracting more reliable heart rates and breath rates [13][14][15].…”
Section: Discussionmentioning
confidence: 99%
“…In general, heart rate was measuring through Electrocardiogram(ECG) signal orPhotoplethysmography(PPG)signal [4]. As a novel method,EBI allow us to noninvasively obtain physical information from human body.…”
Section: Introductionmentioning
confidence: 99%