2012
DOI: 10.1016/j.mvr.2011.12.003
|View full text |Cite
|
Sign up to set email alerts
|

A method for quantitative characterization of growth in the 3-D structure of rat pulmonary arteries

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
31
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(32 citation statements)
references
References 24 publications
1
31
0
Order By: Relevance
“…Our data exhibited a similar trend to that of Lee et al The slightly larger values obtained by Lee et al were likely the result of the fact that their measurements were made in older rats (27). Sera et al (29) reported an average D/D P value of 0.89 for the rat airways, measured using microfocal X-ray CT, which is similar to our value of 0.80 (SD 0.22).…”
Section: Airwaysupporting
confidence: 90%
“…Our data exhibited a similar trend to that of Lee et al The slightly larger values obtained by Lee et al were likely the result of the fact that their measurements were made in older rats (27). Sera et al (29) reported an average D/D P value of 0.89 for the rat airways, measured using microfocal X-ray CT, which is similar to our value of 0.80 (SD 0.22).…”
Section: Airwaysupporting
confidence: 90%
“…Methods to provide contrast for the pulmonary arteries against the lung parenchyma in micro-CT imaging have been described previously (3,28). Briefly, pulmonary arteries were infused with a radiopaque contrast agent in banded (n ϭ 7) and sham-operated (n ϭ 6) animals.…”
Section: Arterial Castingmentioning
confidence: 99%
“…Fixed heart and lungs samples after arterial casting were imaged using two different micro-CT scanners (28). To validate the presence of the band around the LPA in the banded group, the fixed tissue samples were first evaluated under X-ray using an eXplore RS micro-CT scanner (GE Healthcare).…”
Section: High-resolution Micro-ct Imagingmentioning
confidence: 99%
See 1 more Smart Citation
“…The latter phenomenon is also important for the understanding of tumor growth and could be used in oncological treatment strategies, especially in patients treated by biological therapy with antibodies against vascular endothelial factor A (bevacizumab), which inhibits neoangiogenesis . Micro-CT imaging of pathological vascularity can provide new information, e.g., about changes in vessel walls in atherosclerosis or other pulmonary vascular diseases (Razavi, 2012).…”
Section: Current Applications Of Micro-ct In Biomechanics and Medicinementioning
confidence: 99%