A method for the estimation of hydration state during hemodialysis using a calf bioimpedance technique

Abstract: Although many methods have been utilized to measure degrees of body hydration, and in particular to estimate normal hydration states (dry weight, DW) in hemodialysis (HD) patients, no accurate methods are currently available for clinical use. Biochemcial measurements are not sufficiently precise and vena cava diameter estimation is impractical. Several bioimpedance methods have been suggested to provide information to estimate clinical hydration and nutritional status, such as phase angle measurement and ratio… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
72
0
2

Year Published

2011
2011
2021
2021

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 72 publications
(76 citation statements)
references
References 34 publications
2
72
0
2
Order By: Relevance
“…5,6,[9][10][11][13][14][15] This wellvalidated technique (accuracy of within 5%; repeatability of within 0.3%) uses impedance to electric current within a body segment to measure its fluid content. 16,17 We then measured the circumferences of the neck above the cricothyroid cartilage and of the thickest portion of the right calf by tape measure just before and after polysomnography as previously described. 5,6 Lines were drawn at these levels with a marker pen to ensure that measurements after sleep were made at exactly the same level as those before sleep.…”
Section: Weight Leg Fluid Volume and Neck And Calf Circumferencesmentioning
confidence: 99%
“…5,6,[9][10][11][13][14][15] This wellvalidated technique (accuracy of within 5%; repeatability of within 0.3%) uses impedance to electric current within a body segment to measure its fluid content. 16,17 We then measured the circumferences of the neck above the cricothyroid cartilage and of the thickest portion of the right calf by tape measure just before and after polysomnography as previously described. 5,6 Lines were drawn at these levels with a marker pen to ensure that measurements after sleep were made at exactly the same level as those before sleep.…”
Section: Weight Leg Fluid Volume and Neck And Calf Circumferencesmentioning
confidence: 99%
“…Approaching normalized resistivity value in the calf provides a secondary indication of DW. The system used is a refinement of the Xitron Hydra multifrequency device which measures both extracellular resistance and resistivity (Zhu et al, 2008a). The algorithm used to determine normal hydration state employs two criteria together: a) flattening of the change in resistance (R E0 /R Et ) curve; and b) normalized resistivity in the range derived from healthy subjects.…”
Section: Combination Of Static and Dynamic Methodsmentioning
confidence: 99%
“…Los cambios de masa magra o los acúmulos de lí-quidos abdominales (cirrosis, ascitis) no se reflejan adecuadamente en las mediciones corporales totales 19 . Además de la determinación de la composición corporal la SBIA se ha utilizado para evaluar la condición de hidratación en pacientes durante la hemodiálisis 20 , monitorizar el desarrollo de edema posquirúrgico en miembros inferiores 21 , evaluar la aparición de linfedema posterior a la resección ganglionar en cáncer de mama 22 , seguimiento del proceso de cicatrización en piel 23 , detección de sarcopenia en adultos mayores 24 y evaluar la presencia y severidad de lesiones musculares agudas 25,26 .…”
Section: Aplicaciones Clínicas De La Bieunclassified