A micro-drive hearing aid: a novel non-invasive hearing prosthesis actuator

Abstract: The direct hearing device (DHD) is a new auditory prosthesis that combines conventional hearing aid and middle ear implant technologies into a single device. The DHD is located deep in the ear canal and recreates sounds with mechanical movements of the tympanic membrane. A critical component of the DHD is the microactuator, which must be capable of moving the tympanic membrane at frequencies and magnitudes appropriate for normal hearing, with little distortion. The DHD actuator reported here utilized a voice c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2016
2016
2017
2017

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 22 publications
0
3
0
Order By: Relevance
“…A typical hearing aid’s THD lies between 2% and 3% [ 36 ]. Considering implantable middle ear hearing device is a kind of implantable hearing aid, many researchers also utilized the THD to assess their implantable middle ear hearing device’s sound quality [ 7 , 22 , 26 ]. The THD of our transducer is displayed in Figure 7 , which has a maximum value of 0.71% at 1.5 kHz.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…A typical hearing aid’s THD lies between 2% and 3% [ 36 ]. Considering implantable middle ear hearing device is a kind of implantable hearing aid, many researchers also utilized the THD to assess their implantable middle ear hearing device’s sound quality [ 7 , 22 , 26 ]. The THD of our transducer is displayed in Figure 7 , which has a maximum value of 0.71% at 1.5 kHz.…”
Section: Resultsmentioning
confidence: 99%
“…Low nonlinear distortions play a significant role in producing high-fidelity sound, especially for speech and music perception [ 25 ]. The total harmonic distortion (THD) is one of the common measures of nonlinear distortion and was utilized by many researchers to assess the implantable middle ear hearing devices’ distortions [ 7 , 22 , 26 ]. To derive the THD of this piezoelectric transducer, we used the function generator (Tektronix AFG3000) to apply a set of single-frequency voltages to the transducer, respectively.…”
Section: Methodsmentioning
confidence: 99%
“…It has been hypothesized that better sound-transmission efficiency might be possible through stimulation of the short process of the malleus rather than the umbo (Paulick et al, 2014). To test this hypothesis, the MSG and EPO are calculated for a force applied at the short process of the malleus.…”
Section: Fe Model Calculations Of the Baseline Msg And Epomentioning
confidence: 99%