A microdialysis technique for continuous subcutaneous glucose monitoring in diabetic patients (part 1)

Abstract: The performances and the stability of a novel subcutaneous glucose monitoring system have been evaluated. GlucoDay † (A. Menarini I.F.R. S.r.l, Florence Italy) is a portable instrument provided with a micro-pump and a biosensor coupled to a microdialysis system capable of recording the subcutaneous glucose level every 3 min. Long and short term stability of the biosensor are discussed and the results of some critical in vitro and in vivo (on rabbits) experiments are reported. A linear response up to 30 mM has … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
56
0

Year Published

2005
2005
2016
2016

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 91 publications
(60 citation statements)
references
References 14 publications
4
56
0
Order By: Relevance
“…With the use of a validated continuous glucose-monitoring system (Maran et al, 2002;Poscia et al, 2003;Varalli et al, 2003;Maran et al, 2004;Wentholt et al, 2005), we assessed 24 h blood glucose concentrations in long-standing type 2 diabetes patients under strict dietary standardization but otherwise free-living conditions. Despite a healthy, balanced diet and the continued use of oral blood glucoselowering medication (ADA 2006), these type 2 diabetes patients showed substantial hyperglycemia throughout the greater part of the day.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…With the use of a validated continuous glucose-monitoring system (Maran et al, 2002;Poscia et al, 2003;Varalli et al, 2003;Maran et al, 2004;Wentholt et al, 2005), we assessed 24 h blood glucose concentrations in long-standing type 2 diabetes patients under strict dietary standardization but otherwise free-living conditions. Despite a healthy, balanced diet and the continued use of oral blood glucoselowering medication (ADA 2006), these type 2 diabetes patients showed substantial hyperglycemia throughout the greater part of the day.…”
Section: Discussionmentioning
confidence: 99%
“…A detailed description of the device is provided elsewhere (Poscia et al, 2003;Varalli et al, 2003).…”
Section: Continuous Glucose Monitoring Systemmentioning
confidence: 99%
“…Poscia and colleagues found the GlucoDay RAD to be 20% in rabbits (19) and 15% in a mixed type 1/type 2 diabetic population (20).…”
Section: Technologies -Five Cgms Have Been Approved By the Us Food mentioning
confidence: 99%
“…Standard techniques such as immunoassays, gel electrophoresis and nuclear magnetic resonance typically cannot be performed in live cells and tissues, or at least they require preparation steps that inhibit real-time measurements [1]. Instead, electrochemical sensing based on oxidases is suitable for real-time monitoring of metabolites, such as glucose [2] and lactate [3].…”
Section: Introductionmentioning
confidence: 99%