2022
DOI: 10.1007/s00216-022-04296-w
|View full text |Cite
|
Sign up to set email alerts
|

A microfluidic chip using Au@SiO2 array–based highly SERS-active substrates for ultrasensitive detection of dual cervical cancer–related biomarkers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2025
2025

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(5 citation statements)
references
References 39 publications
0
5
0
Order By: Relevance
“…Such a test allows the detection of CEA and SCCA, in which the LOD in human serum was 0.36 pg mL À 1 and 0.37 pq mL À 1 , respectively. [182] Ag NPs are also used in cancer therapy. The conducted research shows that Ag@SiO 2 nanostructures can be a potential replacement for currently used photosensitizers used in PDT therapy.…”
Section: Application In Therapy and Diagnosis Of Cancermentioning
confidence: 99%
See 1 more Smart Citation
“…Such a test allows the detection of CEA and SCCA, in which the LOD in human serum was 0.36 pg mL À 1 and 0.37 pq mL À 1 , respectively. [182] Ag NPs are also used in cancer therapy. The conducted research shows that Ag@SiO 2 nanostructures can be a potential replacement for currently used photosensitizers used in PDT therapy.…”
Section: Application In Therapy and Diagnosis Of Cancermentioning
confidence: 99%
“…The biosensor constructed in this way is characterized by extraordinary accuracy and sensitivity and also enables the detection of both biomarkers in parallel. Such a test allows the detection of CEA and SCCA, in which the LOD in human serum was 0.36 pg mL −1 and 0.37 pq mL −1 , respectively [182] . Ag NPs are also used in cancer therapy.…”
Section: Medical Application Of Ag/au@silica Core‐shell Nanostructuresmentioning
confidence: 99%
“…LODs of 6 pg/m for SCCA and 5 pg/mL for survivin were achieved with a linear dynamic range for both analytes from 10 pg/mL to 10 μg/mL. Finally, the simultaneous determination of SCCA and CEA, also targeting cervical cancer, was performed in a microfluidic chip consisting of six functional units with a pump-free design that enabled parallel detection of multiple samples on an array of SiO 2 particles decorated with Au nanoparticles and modified with the respective antibodies in combination with Ag nanocubes labeled with Raman tags and modified with analyte-specific antibodies [ 146 ]. The LODs of SCCA and CEA achieved were 0.45 pg/mL and 0.36 pg/mL, respectively, with a dynamic range from 1 pg/mL to 1 μg/mL.…”
Section: Cancer Biomarkers Immunochemical Detection Via Sersmentioning
confidence: 99%
“…The amalgamation of microfluidics with nanomaterials has yielded innovative approaches to detecting cancer-related biomarkers [ 289 ]. Gu et al [ 290 ] have fabricated a microfluidic detection platform based on an Au@SiO 2 array with a highly surface-enhanced Raman scattering (SERS) active substrate that permits the simultaneous detection of squamous cell carcinoma antigen and carcinoembryonic antigen in clinical serum samples, underscoring the potential of microfluidic chips for clinical cervical cancer diagnosis. Drug intervention, such as tannin from Spatholobi Caulis (TTS), has also emerged as a significant treatment modality for cervical cancer.…”
Section: Microfluidic Chips For Gynecological Diseasesmentioning
confidence: 99%