2020
DOI: 10.3390/lubricants8070072
|View full text |Cite
|
Sign up to set email alerts
|

A Mixed Elasto-Hydrodynamic Lubrication Model for Wear Calculation in Artificial Hip Joints

Abstract: The aim of this paper was to propose a novel in silico mixed elasto-hydrodynamic lubrication model with the purpose of wear prediction in Total Hip Replacements (THRs). The model considers the progressive wear contribution in the calculation of the meatus filled by the non-Newtonian synovial fluid. The results were referred to the gait cycle kinematics, calculated by using musculoskeletal multibody software, while the loading was assumed by literature in vivo measurements. The simulations allow evaluat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
4
1

Relationship

0
9

Authors

Journals

citations
Cited by 24 publications
(24 citation statements)
references
References 34 publications
0
24
0
Order By: Relevance
“…In the next research, the wear on the cup may be calculated using Saputra wear model (Saputra et al, 2019). The wear calculation to involve the lubrication, it may be calculated using Ruggiero wear model (Ruggiero and Sicilia, 2020).…”
Section: Discussionmentioning
confidence: 99%
“…In the next research, the wear on the cup may be calculated using Saputra wear model (Saputra et al, 2019). The wear calculation to involve the lubrication, it may be calculated using Ruggiero wear model (Ruggiero and Sicilia, 2020).…”
Section: Discussionmentioning
confidence: 99%
“…However, several experimental investigations focus on improving the tribological effectiveness of joint replacements [21][22][23] and lubrication conditions in prostheses [24][25][26], some experimental investigations are complemented with computer-aided or computational methods to improve the prediction and findings [27][28][29]. Nevertheless, the exact interactions of coating process parameters and resulting properties are mostly qualitative and only valid for certain coating plants and in certain parameter ranges.…”
Section: Amorphous Carbon Coating Designmentioning
confidence: 99%
“…It should be noted that in recent years it has become practically the norm to represent synovial fluid as a non-Newtonian fluid, since the results of solving most problems become more plausible even with significant simplifications of other elements and parameters of lubrication models [52,[59][60][61][62][63]. The only problem that arises in this case is a certain complication of the mathematical side of the problem.…”
Section: Mathematical Models Of Squeeze Film Lubricationmentioning
confidence: 99%