2022
DOI: 10.1016/j.heliyon.2022.e10214
|View full text |Cite
|
Sign up to set email alerts
|

A modified LC-MS/MS method for the detection of whole blood tacrolimus and its clinical value in Chinese kidney transplant patients

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 30 publications
0
5
0
Order By: Relevance
“…The separation of the two analytes was performed in 2.5 min with high accuracy and precision. The detection limit for both drugs was largely improved in this work as well (0.100-100 ng/ml for tacrolimus and 2.00-2,000 ng/ml for cyclosporine A) compared with the 0.3 ng/ml of tacrolimus reported by Yu et al (2022), Krnáč et al (2019) and Mei et al (2018), with which it was difficult to satisfy the TDM demand in clinical.…”
Section: Analytementioning
confidence: 75%
See 1 more Smart Citation
“…The separation of the two analytes was performed in 2.5 min with high accuracy and precision. The detection limit for both drugs was largely improved in this work as well (0.100-100 ng/ml for tacrolimus and 2.00-2,000 ng/ml for cyclosporine A) compared with the 0.3 ng/ml of tacrolimus reported by Yu et al (2022), Krnáč et al (2019) and Mei et al (2018), with which it was difficult to satisfy the TDM demand in clinical.…”
Section: Analytementioning
confidence: 75%
“…However, in their study, the samples were observed to be dirty and the internal normalized matrix effect factor of cyclosporine A was between 133.6 and 167.2%. Ke‐Wei Yu et al introduced an improved LC–MS/MS method for the detection of tacrolimus in whole blood and its clinical application in kidney transplant patients in China (Yu et al, 2022). The method was designed with two HPLC systems coupled with mass spectrometry to achieve the detection of two samples within 3.5 min.…”
Section: Resultsmentioning
confidence: 99%
“…Creatinine was measured using the Roche enzymatic assay, which has been reported to have an impression of 2.3%. 31 eGFR was calculated using both the modified Schwartz formula for patients younger than 18 years of age and the Cockroft-Gault formula for patients 18 years of age and older, 32,33 as well as the Pottel Full Age Spectrum for height formula for all ages. 34 Using the reference date of the LCPT prescription, eGFR values were calculated for converted patients nearest to time points of −6 months, 0 months, 6 months, and 12 months.…”
Section: Me Thodsmentioning
confidence: 99%
“…However, there have been several reported cases of falsely elevated tacrolimus levels post-transplant, hypothesized to be due to circulating endogenous heterophile antibodies binding to the reagent, animal antibodies, used in the assay [6][7][8]. Liquid chromatography and tandem mass spectrometry (LC-MS) is considered the gold standard for monitoring tacrolimus levels due to its selectivity, sensitivity, and specificity [9][10][11]. However, LC-MS is not often used because it is time-intensive and more expensive.…”
Section: Introductionmentioning
confidence: 99%