2022
DOI: 10.3390/ma15155288
|View full text |Cite
|
Sign up to set email alerts
|

A Multimethod Assessment of a New Customized Heat-Treated Nickel–Titanium Rotary File System

Abstract: This study aimed to compare three endodontic rotary systems. The new Genius Proflex (25/0.04), Vortex Blue (25/0.04), and TruNatomy (26/0.04v) instruments (n = 41 per group) were analyzed regarding design, metallurgy, and mechanical performance, while shaping ability (untouched canal walls, volume of removed dentin and hard tissue debris) was tested in 36 anatomically matched root canals of mandibular molars. The results were compared using one-way ANOVA, post hoc Tukey, and Kruskal–Wallis tests, with a signif… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 22 publications
0
11
0
Order By: Relevance
“…The analysis of centring ability (canal transportation/centroid shift) was not performed in the present study because the selection criteria included only root canals with moderate curvature and tested instruments had a very high flexibility, demonstrated by their transformation temperature curves (Figure 3) and bending load results (Table 1). In these conditions, it is unlikely that clinical relevant changes in the original canal curvature could be noticed, as previously reported (Gagliardi et al, 2015;Silva et al, 2023;Silva, Lima, et al, 2022;Silva, Martins, et al, 2022). Therefore, future studies are suggested to compare the ability of instruments produced by EDM technology to prepare severely curved canals.…”
Section: Cutting Depthmentioning
confidence: 86%
“…The analysis of centring ability (canal transportation/centroid shift) was not performed in the present study because the selection criteria included only root canals with moderate curvature and tested instruments had a very high flexibility, demonstrated by their transformation temperature curves (Figure 3) and bending load results (Table 1). In these conditions, it is unlikely that clinical relevant changes in the original canal curvature could be noticed, as previously reported (Gagliardi et al, 2015;Silva et al, 2023;Silva, Lima, et al, 2022;Silva, Martins, et al, 2022). Therefore, future studies are suggested to compare the ability of instruments produced by EDM technology to prepare severely curved canals.…”
Section: Cutting Depthmentioning
confidence: 86%
“…In clinical practice, many other factors, such as operator experience and anatomical complexities, act simultaneously, affecting the mechanical behavior of files used [ 30 , 31 ]. In addition, differences in the mechanical behavior of tested instruments should be determined, considering multiple factors including the phase transformation temperatures of heat-treated alloys [ 32 ]. CM alloys have been extensively investigated [ 28 ], whereas no data are available on T-wire phase transformation temperature.…”
Section: Discussionmentioning
confidence: 99%
“…In the literature, TruNatomy les showed 50-52% of untouched canal surface area which had insigni cant difference when compared to Vortex Blue les [5], but signi cantly higher percentage compared to EdgeFile X3, XP-Shaper, WaveOne Gold, Reciproc Blue, TRUShape and iRace [8, 19,20]. On the other hand, Vortex Blue les resulted in 55-58% of untouched canal surface area with a signi cant higher percentage when compared to XP-Shaper and TRUShape [21][22][23].…”
Section: Discussionmentioning
confidence: 99%
“…Micro-CT imaging technology has been recognized as the most accurate research tool for the study of root canal anatomy and the morphological changes in the root canal system after chemo-mechanical instrumentation [6-8]. To our knowledge, only one study in the literature has conducted a comprehensive assessment of Vortex Blue with TruNatomy les [5].…”
Section: Introductionmentioning
confidence: 99%