Electrostatic Precipitation 2009
DOI: 10.1007/978-3-540-89251-9_147
|View full text |Cite
|
Sign up to set email alerts
|

A Multiple-switch Technology for High-power Pulse Discharging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2011
2011
2011
2011

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…Over a number of experiments conducted with the spark gap and by having an accumulative number of shots exceeding one thousand, power dissipation within the gap resulted in an erosion on the surfaces of both electrodes as shown in Fig.(9). Erosion rate may increase nonlinearly with upgrading current levels [14].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Over a number of experiments conducted with the spark gap and by having an accumulative number of shots exceeding one thousand, power dissipation within the gap resulted in an erosion on the surfaces of both electrodes as shown in Fig.(9). Erosion rate may increase nonlinearly with upgrading current levels [14].…”
Section: Resultsmentioning
confidence: 99%
“…These plasma switches cover thyratrons, pseudospark, and spark gaps [6][7][8]. Because of their simple design and construction, low cost, and capability of current le vel control, spark gaps have stimulated interests in a number of research activities [9][10][11][12][13][14]. In these studies, a number of operating parameters was investigated including repetition rate, discharge region of operation, electrode erosion, gas pressure, and damping conditions of the output signals.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…These plasma switches cover thyratrons, pseudospark, and spark gaps [6][7][8]. Because of their simple design and construction, low cost, and capability of current le vel control, spark gaps have stimulated interests in a number of research activities [9][10][11][12][13][14]. In these studies, a number of operating parameters was investigated including repetition rate, discharge region of operation, electrode erosion, gas pressure, and damping conditions of the output signals.…”
Section: Introductionmentioning
confidence: 99%
“…Characteristic current-voltage curves can then be deduced from the output signals after recording the charging voltage of the capacitor or the energy storage unit. Previous experiments [11][12][13][14][15][16][17] were carried out to study the effect of the breakdown conditions and the plasma characteristics where breakdown could be preceded by corona stabilization in non-uniform electric field geometry. Such studies establish a correlation scheme between charged particle density and its governing parameters.…”
Section: Introductionmentioning
confidence: 99%