X-ray emission has been detected occasionally during the streamer-corona propagation in a wire-plate corona reactor open to ambient air. A 65 kV pulse with 15 ns rise time is applied to the wire anode superimposed on a 20 kV dc bias. The duration of the driving voltage pulse (110 ns) is less than 2.5 times the primary streamer transit time. Under this condition no arc discharge occurs between the wire and the cathode plates separated by 6 cm air. The onset of x-ray emission coincides with the initiation of the primary streamers near the wire anode. No x-rays were detected later, during or after the primary or secondary streamer development. X-ray energies ranged between 10 and 42 keV, as detected by a LaBr3 (Ce) scintillator–photomultiplier combination. Time resolved imaging of the streamer propagation highlights the different stages in the streamer discharge process. The energetic electrons originate near the anode, at the moment of streamer initialization.
• A submitted manuscript is the version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website.• The final author version and the galley proof are versions of the publication after peer review.• The final published version features the final layout of the paper including the volume, issue and page numbers. Link to publication General rightsCopyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.• Users may download and print one copy of any publication from the public portal for the purpose of private study or research.• You may not further distribute the material or use it for any profit-making activity or commercial gain • You may freely distribute the URL identifying the publication in the public portal. Abstract-In this paper, we present a large-bandwidth, highcurrent and high-voltage measuring system for pulse measurements in pulsed power systems. The developed sensors can be easily calibrated, require no extensive (3D) modeling, are very compact, are inexpensive, and have a bandwidth of up to several GHz. Moreover, they can be used in any pulsed power system where a pulse source is connected to its load by a coaxial cable (without disturbing the coaxial geometry).We developed this sensor system for use with our nanosecond pulse source system. The type of sensors we used are Ddot and B-dot sensors, which are compactly mounted on the coaxial cable that connects our nanosecond pulse source to its load. This enables us to measure the characteristics of each sensor very precisely with a vector network analyzer. With these characteristics -combined with the characteristics of the measuring cable assembly -we can numerically reconstruct the voltage and current waveforms that passed the sensor positions. Our calibration approach, the mounting on the coaxial cable and the post-processing of the results make these sensors very flexible. While we use the sensors for energy measurements, camera triggering and the general measurement of the pulses, other researchers can use these type of sensors as well in any system where a (coaxial) cable connects a pulse source to its load.
• A submitted manuscript is the author's version of the article upon submission and before peer-review. There can be important differences between the submitted version and the official published version of record. People interested in the research are advised to contact the author for the final version of the publication, or visit the DOI to the publisher's website.• The final author version and the galley proof are versions of the publication after peer review.• The final published version features the final layout of the paper including the volume, issue and page numbers. Link to publication Citation for published version (APA):Huiskamp, T., Sengers, W., Beckers, F. J. C. M., Nijdam, S., Ebert, U. M., van Heesch, E. J. M., & Pemen, A. J. M. (2017). Spatiotemporally resolved imaging of streamer discharges in air generated in a wire-cylinder reactor with (sub)nanosecond voltage pulses. Plasma Sources Science and Technology, 26(7), 075009. DOI: 10.1088/1361-6595/aa7587General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights.• Users may download and print one copy of any publication from the public portal for the purpose of private study or research.• You may not further distribute the material or use it for any profit-making activity or commercial gain • You may freely distribute the URL identifying the publication in the public portal ? Take down policyIf you believe that this document breaches copyright please contact us providing details, and we will remove access to the work immediately and investigate your claim. Abstract. We use (sub)nanosecond high-voltage pulses to generate streamers in atmospheric-pressure air in a wire-cylinder reactor. We study the effect of reactor length, pulse duration, pulse amplitude, pulse polarity, and pulse rise time on the streamer development, specifically on the streamer distribution in the reactor to relate it to plasma-processing results. We use ICCD imaging with a fully automated setup that can image the streamers in the entire corona-plasma reactor. From the images, we calculate streamer lengths and velocities. We also develop a circuit simulation model of the reactor to support the analysis of the streamer development. The results show how the propagation of the high-voltage pulse through the reactor determines the streamer development. As the pulse travels through the reactor, it generates streamers and attenuates and disperses. At the end of the reactor, it reflects and adds to itself. The local voltage on the wire together with the voltage rise time determine the streamer velocities, and the pulse duration the consequent maximal streamer length.Spatiotemporally resolved imaging of streamer discharges in air generated in a wire-cylinder reactor with (sub
DOI to the publisher's website. • The final author version and the galley proof are versions of the publication after peer review. • The final published version features the final layout of the paper including the volume, issue and page numbers. Link to publication General rights Copyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal requirements associated with these rights. • Users may download and print one copy of any publication from the public portal for the purpose of private study or research. • You may not further distribute the material or use it for any profit-making activity or commercial gain • You may freely distribute the URL identifying the publication in the public portal. If the publication is distributed under the terms of Article 25fa of the Dutch Copyright Act, indicated by the "Taverne" license above, please follow below link for the End User Agreement:
Abstract-For pulsed corona plasma applications, it becomes important to develop pilot systems with large average power and high-energy conversion efficiency. Since the beginning of 2000, we have been working on an industrial corona plasma system with tasks of 10-30 kW in average power and higher than 90% of total energy conversion efficiency. The pulsed-power source should have the following specifications: rise time of 10-25 ns, pulsewidth of 50-150 ns, pulse repetition rate of up to 1000 pulses per second, peak voltage pulse of 70 kV, peak current of 3.5 kA, dc bias voltage of 10-35 kV, and energy per pulse of up to 30 J. Sixteen parallel wire cylinder reactors are used to match the source. Gas and reactor temperatures can be controlled individually with water flow around the outside of those cylinders. The system is designed for gaseous oxidation and electrostatic dust precipitation. The system has been used for up to 17 kW in average power. This paper reports the system in detail, discusses issues related to the matching between the source and the reactor, and presents an example of industrial demonstrations on odor abatement at 1000 m 3 /h. Finally, this paper also gives a general guideline for design of corona plasma systems.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.