2019
DOI: 10.7717/peerj.7086
|View full text |Cite
|
Sign up to set email alerts
|

A new comprehensive eye-tracking test battery concurrently evaluating the Pupil Labs glasses and the EyeLink 1000

Abstract: Eye-tracking experiments rely heavily on good data quality of eye-trackers. Unfortunately, it is often the case that only the spatial accuracy and precision values are available from the manufacturers. These two values alone are not sufficient to serve as a benchmark for an eye-tracker: Eye-tracking quality deteriorates during an experimental session due to head movements, changing illumination or calibration decay. Additionally, different experimental paradigms require the analysis of different types of eye m… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
70
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 93 publications
(70 citation statements)
references
References 71 publications
0
70
0
Order By: Relevance
“…The spatial accuracy of the EyeLink 1000 (SR Research Ltd., Mississauga, Ontario, Canada) is 0.5 degrees [35]. Given the small separation of stimuli, we are unable to determine if saccades were made to stimuli at 0.38º eccentricity.…”
Section: Confirming Fixationmentioning
confidence: 99%
“…The spatial accuracy of the EyeLink 1000 (SR Research Ltd., Mississauga, Ontario, Canada) is 0.5 degrees [35]. Given the small separation of stimuli, we are unable to determine if saccades were made to stimuli at 0.38º eccentricity.…”
Section: Confirming Fixationmentioning
confidence: 99%
“…Ensuring the quality of eye movement data was based on adherence to several aspects, including the suitability of the equipment used [ 30 ], equipment settings, experimental procedure, and the behavior and psychology of participants [ 31 , 32 , 33 ].…”
Section: Methodsmentioning
confidence: 99%
“…The determination of the time interval was based on other studies [37] looking at the attention range of the participants. The subject of interest during the first 15 s was the Ensuring the quality of eye movement data was based on adherence to several aspects, including the suitability of the equipment used [30], equipment settings, experimental procedure, and the behavior and psychology of participants [31][32][33].…”
Section: Introductionmentioning
confidence: 99%
“…Despite the existing challenges associated with simultaneously recording EMs and ERPs (see [26,[88][89][90][91] for a discussion), joint efforts from the international research community, alongside technological advances (see [92][93][94][95] for a discussion) and advances in computational algorithms used for the correction of ocular artifacts [26,[96][97][98][99], have allowed for a third, ongoing, phase of co-registration research to become possible. These studies have involved simultaneously recording EM and ERP data from the same group of participants, reading the same stimuli, and performing the same task.…”
Section: Simultaneous Recording Of Eye Movements and Fixation-relatedmentioning
confidence: 99%