A new control algorithm of active power line conditioner for improving power quality

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
2
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
4
1
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(3 citation statements)
references
References 7 publications
0
2
0
Order By: Relevance
“…Passive filter connected between VSI and injection converter, eliminates harmonic components of high order in outlet voltage of the inverter (Wang et al, 2014;Jena et al, 2015;Elbeji et al, 2014). The VSI power storage device provides the required effective compensation power (Jou et al, 2004). DVR compensation capacity depends on the width of the sags and the size of the energy storage.…”
Section: Dynamic Voltage Restorer (Dvr)mentioning
confidence: 99%
“…Passive filter connected between VSI and injection converter, eliminates harmonic components of high order in outlet voltage of the inverter (Wang et al, 2014;Jena et al, 2015;Elbeji et al, 2014). The VSI power storage device provides the required effective compensation power (Jou et al, 2004). DVR compensation capacity depends on the width of the sags and the size of the energy storage.…”
Section: Dynamic Voltage Restorer (Dvr)mentioning
confidence: 99%
“…The SHAPF filtering characteristics and efficiency of harmonic compensation depend on the control algorithm (CA) applied to calculate the reference voltage. A number of control approaches have been proposed to achieve the desired harmonic compensation using SHAPF . The control techniques reported in the literature to derive the reference voltage for SHAPF may be broadly categorized into three approaches.…”
Section: Introductionmentioning
confidence: 99%
“…Several publications appeared in the literature that suggests different definitions of instantaneous power theories for deriving reference quantities. Instantaneous p‐q theory, dual p‐q theory, synchronous reference frame theory, vectorial theory, generalized a–b–c reference frame theory, and so on are few widely used definitions used by researchers for separating reference for hybrid active filters . Vector algebra is suggested as very useful tool for the definition of power components in three‐phase a–b–c coordinate systems.…”
Section: Introductionmentioning