India International Conference on Power Electronics 2010 (IICPE2010) 2011
DOI: 10.1109/iicpe.2011.5728092
|View full text |Cite
|
Sign up to set email alerts
|

A new direct torque control of doubly fed induction generator for wind power generation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 8 publications
0
5
0
Order By: Relevance
“…Several modifications on the conventionnel DTC are presented in the literature. The vector modulation technique (SVM) has been widely used to ensure a constant switching frequency operation for the RSC . This strategy is characterized by the elimination of the hysteresis controllers and the switching table.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Several modifications on the conventionnel DTC are presented in the literature. The vector modulation technique (SVM) has been widely used to ensure a constant switching frequency operation for the RSC . This strategy is characterized by the elimination of the hysteresis controllers and the switching table.…”
Section: Introductionmentioning
confidence: 99%
“…The vector modulation technique (SVM) has been widely used to ensure a constant switching frequency operation for the RSC. [3][4][5] This strategy is characterized by the elimination of the hysteresis controllers and the switching table. Although better performance was achieved by reducing the switching frequency and improving the steady-state response, the complexity of the system was increased, and more machine parameters were needed.…”
Section: Introductionmentioning
confidence: 99%
“…To eliminate the complicated control structure in VC, direct control approaches like the direct torque control (DTC) [11][12][13] and direct power control (DPC) [14][15][16] were proposed. Compared to the VC approach, the DTC and DPC algorithms are simpler in terms of the controller structure and have shown faster dynamic response because of the use of a predefined switching table for voltage vector selection to replace the multiple inner voltage/ current loops with proportional-integral controllers.…”
Section: Introductionmentioning
confidence: 99%
“…The output reference voltage vectors (RVVs) are generated using either one PI-regulator (cascaded) DTC-SVM [8], [9] or two PI-regulators (parallel) DTC-SVM [10]- [14]. The PI-regulators in torque and flux loops can be further eliminated if model predictive/dead-beat control strategies are used [15], [16].…”
Section: Introductionmentioning
confidence: 99%