2017
DOI: 10.1063/1.4997974
|View full text |Cite
|
Sign up to set email alerts
|

A new dispersion interferometer on HL-2A

Abstract: In order to avoid a fringe jump caused by high plasma density and pellet injection [Y. Zhou et al., Rev. Sci. Instrum. 87, 11E107 (2016)], a new CO dispersion interferometer is designed and commissioned on HL-2A for average line-density measurement and density feedback control. The second harmonic technology in this system eliminates the phase shift caused by mechanical vibration. Signals are processed by a digital phase comparator and can be monitored in real time. A series of experiments are conducted to stu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
16
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 12 publications
(17 citation statements)
references
References 17 publications
1
16
0
Order By: Relevance
“…Additional methods to extract the phase difference from the modulated interference signal also exist. Some DIs [13][14][15][16][17][18] evaluate the phase difference from a ratio of amplitudes of fundamental and second harmonic components of the drive frequency ω m . Eq.…”
Section: Phase Modulationmentioning
confidence: 99%
See 1 more Smart Citation
“…Additional methods to extract the phase difference from the modulated interference signal also exist. Some DIs [13][14][15][16][17][18] evaluate the phase difference from a ratio of amplitudes of fundamental and second harmonic components of the drive frequency ω m . Eq.…”
Section: Phase Modulationmentioning
confidence: 99%
“…For the phase matching, one uses conventional birefringence of a nonlinear material, the other uses the periodic domain inversion structure. For 10 µm wavelength, the former used for the DIs are ZnGeP 2 [11], AgGaSe 2 [13][14][15][16][17][18], and AgGaS. The latter is OP-GaAs [21,22,27,28].…”
Section: Nonlinear Crystalmentioning
confidence: 99%
“…The diagnostic system on the device includes a Rogowski coil to measure the plasma current, a high-speed camera to measure the diameter of the plasma beam, and a new short-wavelength DI system to measure the plasma density. Figure 2 shows the basic principle of the new DIs [2,[5][6][7][8][9][10]. The CO 2 laser emits a probe beam with a frequency of ω and a vertical polarization.…”
Section: The Scu-psi Devicementioning
confidence: 99%
“…The size of the crystal is 5 mm × 5 mm × 15 mm. The conversion efficiency of the crystal is approximately 1 × 10 −6 [2].…”
Section: The Scu-psi Devicementioning
confidence: 99%
See 1 more Smart Citation