2014
DOI: 10.1016/j.ijepes.2013.08.012
|View full text |Cite
|
Sign up to set email alerts
|

A new fast-converged estimation approach for Dynamic Voltage Restorer (DVR) to compensate voltage sags in waveform distortion conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
24
0
4

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 45 publications
(28 citation statements)
references
References 25 publications
0
24
0
4
Order By: Relevance
“…For detection and analysis of voltage events (voltage sag and swell) in distribution system Kalman filter have been used. The Kalman filtering method gives the information on both magnitude and phase angle of the supply voltage during the voltage sag and swell events and the point-on-wave where the voltage events begin unlike the RMS method [18], [20], [81], [98], [121], [145], [212].…”
Section: Kalman Filtering Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…For detection and analysis of voltage events (voltage sag and swell) in distribution system Kalman filter have been used. The Kalman filtering method gives the information on both magnitude and phase angle of the supply voltage during the voltage sag and swell events and the point-on-wave where the voltage events begin unlike the RMS method [18], [20], [81], [98], [121], [145], [212].…”
Section: Kalman Filtering Methodsmentioning
confidence: 99%
“…The most popular form of pulse width modulation (PWM) synthesis is the sinusoidal pulse width modulation (S-PWM) [20], [47], [77], [80][81][82], [107], [111], [112], [117], [125], [126], [130], [203], [205], [207]. In an S-PWM scheme the modulating signal is sinusoidal and carrier signal is a triangular wave.…”
Section: Sinusoidal Pulse Width Modulation (Spwm) Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The neural network architecture is adopted for pattern recognition and is used along with fuzzy controller for power disturbance detection [101]. A robust detection method with least estimation error when compared to KF and FFT algorithms gives excellent results during frequency varying conditions and sags with and without phase jumps [102]. The twopoint approach based period phase method of voltage sag/swell magnitude and phase jump detection introduced in [96] is easy to realize and is popularly used among three phase and single phase power lines.…”
Section: Control Techniques Of the Dvrmentioning
confidence: 99%
“…DGİ hassas yüklerde gerilim bozukluklarının etkilerini azaltmak amacı ile şebekeye seri olarak denetimli gerilim basmaktadır [16][17][18][19]. Şekil 2'de gösterilen sistemde, DGİ üç faz şebeke (11 kVpp) ve hassas yük (1 MVA) arasında birleştirilmektedir.…”
Section: Si̇stem Yapisi (The System Structure)unclassified