2014
DOI: 10.1016/j.ijepes.2013.10.027
|View full text |Cite
|
Sign up to set email alerts
|

A new method for non-unit protection of power transmission lines based on fault resistance and fault angle reduction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
11
0

Year Published

2014
2014
2024
2024

Publication Types

Select...
5
2

Relationship

3
4

Authors

Journals

citations
Cited by 12 publications
(11 citation statements)
references
References 17 publications
0
11
0
Order By: Relevance
“…First, we define the following parameters [3]: T f is the occurrence time of the fault; f u is the voltage frequency; T k is the nearest zero-cross moment, at which the voltage changes from negative to positive, to T f ; Â u is the voltage phase angle at the relay site.…”
Section: Fault Initial Anglementioning
confidence: 99%
See 2 more Smart Citations
“…First, we define the following parameters [3]: T f is the occurrence time of the fault; f u is the voltage frequency; T k is the nearest zero-cross moment, at which the voltage changes from negative to positive, to T f ; Â u is the voltage phase angle at the relay site.…”
Section: Fault Initial Anglementioning
confidence: 99%
“…Hence, protection algorithms constructed by fault transient component can meet the performance requirement of ultra-high-speed action [2]. As a result, busbar protection based on fault transient component for EHV line protection has been widely discussed [3,4]. In [5], transient component generated by fault was applied to busbar protection for the first time wherein wavelet transform was utilized to extract the fault features.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Nowadays, most medium voltage distribution networks in China employ an ineffectively grounded (i.e., isolated or a anti-arc coil grounded) neutral to reduce overvoltage caused by SPG faults [1,2]. As a result, the very low fault current and unstable fault arcs make it difficult to detect faulty lines during SPG faults [3][4][5]. When a SPG fault occurs, the anti-arc coil over-compensates the total capacitive current in the network, and the residual fault current is not seriously harmful to the power supply equipment in a short time, but on the other hand it may leads to deadly consequences if the faulty line is not isolated from the distribution network in time, so it is very necessary to detect and isolate the faulty line automatically to ensure the reliability of the distribution automation and power supply.…”
Section: Introductionmentioning
confidence: 99%
“…In order to enhance the reliability of transient protection significantly, as indicated in [17], a new protection method with ultra-high speed was put forward for extra-high-voltage transmission lines, by which the adverse influence caused by fault initial angle (FIA) and transient resistance (TR) can be effectively reduced. Nevertheless, the traditionally fixed setting value was still adopted as the protection criterion in the method, i.e.…”
Section: Introductionmentioning
confidence: 99%