1982
DOI: 10.1002/jhrc.1240050203
|View full text |Cite
|
Sign up to set email alerts
|

A new method for the quantitative analysis of organochlorine pesticides and polychlorinated biphenyls

Abstract: A simple method is described for the quantitative determination of organochlorine pesticides and polychlorinated biphenyls (PCB's) in water at the sub‐ppb level. A micro gas‐phase extractor advantageously replaces other preconcentration and purification techniques. The extract is analyzed by capillary gas chromatography without further enrichment. The recovery at the ppb level was nearly 100% for organochlorine pesticides and more than 80% for PCB's. The complete procedure including sample preparation, steam d… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
7
0
2

Year Published

1983
1983
2010
2010

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 56 publications
(9 citation statements)
references
References 19 publications
0
7
0
2
Order By: Relevance
“…In this respect, the simultaneous steam distillation-solvent extraction technique (SDE) (10,11) has proved its usefulness for enriching different types of samples (12)(13)(14)(15)(16). Our previous research demonstrated the potential of SDE for distinguishing between different edible oils on the basis of the study of compositional differences, although detection of adulterations of olive oil with hazelnut oil below 15% was not achieved (17).…”
mentioning
confidence: 99%
“…In this respect, the simultaneous steam distillation-solvent extraction technique (SDE) (10,11) has proved its usefulness for enriching different types of samples (12)(13)(14)(15)(16). Our previous research demonstrated the potential of SDE for distinguishing between different edible oils on the basis of the study of compositional differences, although detection of adulterations of olive oil with hazelnut oil below 15% was not achieved (17).…”
mentioning
confidence: 99%
“…Verzele et a/. have described a micro version of this apparatus which provides a concentrated extract suitable for capillary column gas chromatographic analysis [14,15]. The apparatus can handle 10-1 00 mL of aqueous solution or 1 -20 g of solid material blended with water and provides an extraction of the distillate into 1.0 mL of pentane or methylene chloride.…”
Section: Isolation and Concentration Techniques Using Physical Methodsmentioning
confidence: 99%
“…Os dados da tabela 2 indicam que, de maneira geral, as repetibilidades conseguidas nos pré-processamentos das amostras podem ser consideradas bastante satisfatórias, pois de 19 valores tabelados, 15 estão abaixo de s R = 5%. O nível de s R = 5% é considerado por vários autores como representativo de boa qualidade químico-analítica para o tipo de pré-processamento de amostra aqui discutido 9,11,14 ; por outro lado, s R de 10% ou mais também já foram reportados em trabalhos quantitativos 2 . Os resultados apresentados na tabela 2 também indicam que, para os cinco compostos, a variação das eficiências de extração entre 53,6% (s R = 2,8) e 100% (s R = 1,0) não prejudica as suas análises quantitativas por CGAR-DCE, o que é apoiado pelos resultados mostrados na figura 3.…”
Section: Avaliação Do Efeito Das Concentrações Dos Analitos Sobre As unclassified
“…Resultados analíticos obtidos com o microextrator, tanto na forma original 10 , quanto após modificações 11 ,indicaram potencialidades desta metodologia de extração e pré-concentração em uma única etapa, que motivaram os estudos aqui relatados, de exploração deste dispositivo para análises de pesticidas organoclorados em águas. Foram construídos e testados dois modelos de microextratores, que têm geometrias modificadas em relação à originalmente proposta 9 . Os testes realizados, com pré-processamentos de amostras aquosas de hexaclorobenzeno, lindano, aldrin, endrin e dieldrin, seguidos de análise por CGAR-DCE, revelaram que um dos microextratores possibilita extrações com rendimentos e repetibilidades apropriadas para as análises cromatográficas destes pesticidas.…”
Section: Introductionunclassified