2011 IEEE Power and Energy Society General Meeting 2011
DOI: 10.1109/pes.2011.6039315
|View full text |Cite
|
Sign up to set email alerts
|

A new protection principle for HVDC transmission lines based on fault component of voltage and current

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
14
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 17 publications
(14 citation statements)
references
References 5 publications
0
14
0
Order By: Relevance
“…In (19), H2 ≠ 0 for the small reflection travelling wave u r . However, H2 < H1 based on (18) and (19).…”
Section: The Influences By the Rectifiermentioning
confidence: 86%
See 1 more Smart Citation
“…In (19), H2 ≠ 0 for the small reflection travelling wave u r . However, H2 < H1 based on (18) and (19).…”
Section: The Influences By the Rectifiermentioning
confidence: 86%
“…It depends on the accuracy of the transmission line parameters. Recently, the method based on the DC fault current direction [17] or on the fault current and voltage components [18] can locate the fault effectively. However, the protection can only be realised with two-terminal electric quantities.…”
Section: Introductionmentioning
confidence: 99%
“…By this reason, in [5], according to the comparison of the energy of the forward and backward voltage traveling wave, the fault position can be recognized. Moreover, a pilot directional protection scheme for HVDC transmission line is proposed, which extracts the direction feature of specific frequency current through spectrum analysis and integral [6,7]. However, these methods don't have strong robustness to noise because the integral cannot get rid of noise disturbance and the fault current energy would be low and the integral would be much smaller when a high-resistance fault occurs.…”
Section: Introductionmentioning
confidence: 99%
“…In this paper, a novel algorithm for transmission line protection is proposed following the principle of relative entropy of wavelet energy, having improved the reliability of protection method proposed in [7] under high resistance grounding fault conditions and its anti-noise property. Furthermore, the proposal is based on the analysis of the HVDC transmission system and its superimposed circuit which indicate the directional features of the voltage and current.…”
Section: Introductionmentioning
confidence: 99%
“…Failure statistics on Tianshengqiao-Guangzhou HVDC project (China, 1800 MW, 6500 kV) showed that transmission line faults were 50% of the total system faults from 2001 to 2007 (Li et al, 2009). To control and protect HVDC transmission lines, direct current measurement equipment must be installed in converter stations to provide reliable and accurate measured values (Xing et al, 2011;Yu et al, 2002).…”
Section: Introductionmentioning
confidence: 99%