1999
DOI: 10.1152/ajpheart.1999.276.5.h1801
|View full text |Cite
|
Sign up to set email alerts
|

A new sample-processing unit for the fluorescent microsphere method

Abstract: The use of fluorescent-labeled microspheres (FM) for measurement of regional blood flow is an attractive alternative to the use of radioactive-labeled microspheres. In the FM method the FM have to be completely recovered from the tissue samples in a time- and labor-intensive process. For this reason, a considerable loss of FM is possible. The aim of this study was to develop a filtration device that allows the tissue sample to remain in a single container throughout the procedure to make the process easier and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
48
0

Year Published

2003
2003
2013
2013

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 39 publications
(48 citation statements)
references
References 5 publications
0
48
0
Order By: Relevance
“…The left jugular vein was used for injection of adenosine (300 g ⅐ kg Ϫ1 ⅐ min Ϫ1 over 10 s) to induce maximum coronary blood flow, which was confirmed by a significant drop in LV systolic blood pressure and heart rate (Ͼ20%) immediately after injection of adenosine. Fluorescence was extracted from digested tissue and reference blood sample by the method of Raab et al (25). Fluorescence intensity was measured with a luminescence spectrometer (model LS55B, PerkinElmer) at the optimal excitation-emission wavelength pair for each dye (blue, 365 and 415 nm; orange, 520 and 560 nm) with excitation and emission slit widths of 4 nm in scanning mode.…”
Section: Methodsmentioning
confidence: 99%
“…The left jugular vein was used for injection of adenosine (300 g ⅐ kg Ϫ1 ⅐ min Ϫ1 over 10 s) to induce maximum coronary blood flow, which was confirmed by a significant drop in LV systolic blood pressure and heart rate (Ͼ20%) immediately after injection of adenosine. Fluorescence was extracted from digested tissue and reference blood sample by the method of Raab et al (25). Fluorescence intensity was measured with a luminescence spectrometer (model LS55B, PerkinElmer) at the optimal excitation-emission wavelength pair for each dye (blue, 365 and 415 nm; orange, 520 and 560 nm) with excitation and emission slit widths of 4 nm in scanning mode.…”
Section: Methodsmentioning
confidence: 99%
“…Fluorescence was extracted from digested tissue and a reference blood sample with Raab's method. 21 Fluorescence intensity was measured with a luminescence spectrometer (model LS55B, Perkin-Elmer) at the optimal excitation/emission wavelength pair of each dye (blue, 365 and 415 nm; orange, 520 and 560 nm) with excitation and emission slit widths of 4 nm in scanning mode. Myocardial blood flow was subsequently calculated as outlined in the Molecular Probes product manual.…”
Section: Myocardial Blood Flow and Hemodynamicsmentioning
confidence: 99%
“…The robotic system was used to recover the FM of the tissue samples so that the fluorescence intensities could be measured with a luminescence spectrophotometer and an automated sampling unit (Perkin Elmer, Überlingen, Germany) to calculate organ blood flow. 15,16 …”
Section: Downloaded Frommentioning
confidence: 99%