Fig. 1 a, Orthogonal polarization spectral imaging probe. b, Optical schematic of the OPS imaging probe. A typical magnification of ×10 is maintained between the target and its image. This results in a resolution of approximately 1 µm/pixel, which is limited by the dimension of the CCD pixel. The probe can be focused from the target surface to 1.0-mm depth, depending on the type of target and the optics used. In vivo, the typical depth of focus is approximately 0.2 mm. c, Optical density of a graduated gray scale (catalog number 152-7662; Kodak) was measured in the presence of the polarization analyzer (b) or with a 0.5 OD neutral density filter (ć) used in place of the analyzer. Average light intensity for each gray level was converted to OD by the following formula: OD = log 10 ((I m -I d )/(I max -I d )) where I m = measured light intensity, I d = dark light intensity (obtained using a black velvet target), I max = intensity of white target. NEW TECHNOLOGYDifferent disease states, including diabetes, hypertension and coronary heart disease, produce distinctive microvascular pathologies. So far, imaging of the human microcirculation has been limited to vascular beds in which the vessels are visible and close to the surface (for example, nailfold, conjunctiva). We report here on orthogonal polarization spectral (OPS) imaging, a new method for imaging the microcirculation using reflected light that allows imaging of the microcirculation noninvasively through mucus membranes and on the surface of solid organs. In OPS imaging, the tissue is illuminated with linearly polarized light and imaged through a polarizer oriented orthogonal to the plane of the illuminating light. Only depolarized photons scattered in the tissue contribute to the image. The optical response of OPS imaging is linear and can be used for reflection spectrophotometry over the wide range of optical density typically achieved by transmission spectrophotometry. A comparison of fluorescence intravital microscopy with OPS imaging in the hamster demonstrated equivalence in measured physiological parameters under control conditions and after ischemic injury. OPS imaging produced high-contrast microvascular images in people from sublingual sites and the brain surface that appear as in transillumination. The technology can be implemented in a small optical probe, providing a convenient method for intravital microscopy on otherwise inaccessible sites and organs in the awake subject or during surgery for research and for clinical diagnostic applications.At present, the use of microvascular imaging in diagnosis and treatment of human disease is limited. Use has been made of nailfold capillaroscopy in the diagnosis and treatment of peripheral vascular diseases, diabetes and hematological disorders 1-3 . Problems with movement have restricted the use of the bulbar conjunctiva for clinical applications in opthalmology 4-6 . Other locations observed by intravital microscopy include the microcirculation of the skin, lip, gingival tissue and tongue 4 . Laser-sca...
Little is known about the microvascular perfusion of the skin postnatally. Skin microvascular parameters can be assessed noninvasively with orthogonal polarization spectral imaging (OPS), a technique where, through the use of special optics, a virtual light source is created at a depth of 1 mm within the tissue. The light is absorbed by the Hb, yielding an image of the illuminated Hb-carrying structures in negative contrast. In nine term (weight 2100 -4470 g) and 28 preterm infants (weight 550 -2070 g; gestational age 24 -33 wk) red blood cell velocity and vessel diameter and density were determined off-line with the CapImage program in vessels video-recorded by OPS near the axilla on d 1 and 5 of life. Blood pressure, heart rate, hematocrit, and body and incubator temperature were noted. Vessel diameter ranged from 6 to 24 m, vessel density from 219 to 340 cm/cm 2 with no change between d 1 or 5 and no difference between term and preterm infants. Red blood cell velocity increased in preterm infants from d 1 [median 528 m/s, 95% confidence interval (CI) 486 -564 m/s] to d 5 (median 570 m/s; 95% CI 548 -662 m/s; p ϭ 0.001) and correlated with the decrease in median hematocrit from 44% (CI 40%-60%) to 39% (CI 37%-43%) with r 2 ϭ Ϫ0.37 with a 95% CI Ϫ0.59 to Ϫ0.11, p ϭ 0.006. Hematocrit correlates with red blood cell velocity in the microvessels of the skin. The new technology can be used to assess quantitative changes in the microvessels and thus allows noninvasive assessment of tissue perfusion in term and preterm infants. At birth, the skin is richly supplied by a dense subepidermal plexus that shows relatively little regional variation. Even the middle and deep dermis are richly endowed with vasculature. The mature pattern of capillary loops and of the subpapillary venous plexus is not present at birth. With exception of the palms, soles, and nail beds, the skin at birth has almost no papillary loops, but demonstrates a disorderly capillary network. By the end of the first week of life, the capillary network assumes a more orderly pattern. Papillary loops begin to appear as small superficial dilatations or buds in the second week and cooling of the skin appears to encourage maturation. The skin architecture in newborns is notably different from those of an adult. Whereas the latter regularly shows loops of capillaries running orthogonal to the surface of the skin, the neonate has a more horizontal structure, which is readily seen through the very thin upper layers (1-4).Cardiac output normalized to mass is much higher in the newborn than in the adult. Because of the high resting cardiac output of neonates there is limited reserve to further augment blood flow under stress. Perfusion pressure is maintained by redistributing marginal cardiac output and oxygen supply to brain, heart, and adrenal gland. Under no stress conditions the skin has high blood flow in relation to its oxygen requirement. Assessment of skin perfusion is therefore of great interest, but there is only very scant data about the microcirculator...
The use of fluorescent-labeled microspheres (FM) for measurement of regional blood flow is an attractive alternative to the use of radioactive-labeled microspheres. In the FM method the FM have to be completely recovered from the tissue samples in a time- and labor-intensive process. For this reason, a considerable loss of FM is possible. The aim of this study was to develop a filtration device that allows the tissue sample to remain in a single container throughout the procedure to make the process easier and to avoid the loss of FM. The core of the sample-processing unit (SPU) is a single-tube filtration device with a polyamide wire mesh. The protocol for processing tissue from different organs (heart, kidney, liver, spleen, intestine, muscle, bone, lung, brain) was modified and thus shortened significantly. Furthermore, the SPU allows direct filtration of the blood reference sample without previous digestion. Different experiments showed that the SPU in combination with the new protocol excludes the loss of 15-μm FM. The modifications of the whole procedure render it faster and highly standardized.
The CytoscanTM Model E-II (Cytometrics Inc., Philadelphia, Pa., USA) is a newly developed instrument which functions as an intravital microscope and is small and easily portable. Through the use of orthogonal polarization spectral (OPS) imaging, the Cytoscan Model E-II delivers images of the microcirculation which are comparable to those achieved with intravital fluorescence videomicroscopy (IFM), but without the use of fluorescent dyes. The purpose of this study was to validate the Cytoscan Model E-II instrument against IFM. The experiments were carried out on striated muscle in the dorsal skinfold chamber of the awake Syrian hamster. The following parameters were measured in identical regions of interest in the same animal under baseline conditions and 0.5 and 2 h after a 4-hour period of pressure-induced ischemia: arteriolar diameter, venular diameter and venular red blood cell velocity. Bland-Altman plots showed good agreement between the two techniques for venular red blood cell velocity. As expected, arteriolar and venular diameters as measured by the Cytoscan were on average 5 µm smaller than the values from IFM, since the Cytoscan measures the red blood cell column width and IFM measures luminal diameter. Thus, OPS imaging can be used to make valid measurements of microvascular diameter and red blood cell velocity in tissues.
Tumour angiogenesis plays a key role in tumour growth, formation of metastasis, detection and treatment of malignant tumours. Recent investigations provided increasing evidence that quantitative analysis of tumour angiogenesis is an indispensable prerequisite for developing novel treatment strategies such as anti-angiogenic and antivascular treatment options. Therefore, it was our aim to establish and validate a new and versatile imaging technique, that is orthogonal polarisation spectral TM imaging, allowing for non-invasive quantitative imaging of tumour angiogenesis in vivo. Experiments were performed in amelanotic melanoma A-MEL 3 implanted in a transparent dorsal skinfold chamber of the hamster. Starting at day 0 after tumour cell implantation, animals were treated daily with the anti-angiogenic compound SU5416 (25 mg kg bw 71 ) or vehicle (control) only. Functional vessel density, diameter of microvessels and red blood cell velocity were visualised by both orthogonal polarisation spectral TM imaging and fluorescence microscopy and analysed using a digital image system. The morphological and functional properties of the tumour microvasculature could be clearly identified by orthogonal polarisation spectral TM imaging. Data for functional vessel density correlated excellently with data obtained by fluroescence microscopy (y=0.99x+0.48, r 2 =0.97, R S =0.98, precision: 8.22 cm 71 and bias: 70.32 cm 71 ). Correlation parameters for diameter of microvessels and red blood cell velocity were similar (r 2 =0.97, R S =0.99 and r 2 =0.93, R S =0.94 for diameter of microvessels and red blood cell velocity, respectively). Treatment with SU5416 reduced tumour angiogenesis. At day 3 and 6 after tumour cell implantation, respectively, functional vessel density was 4.8+2.1 and 87.2+10.2 cm 71 compared to values of control animals of 66.6+10.1 and 147.4+13.2 cm 71 , respectively. In addition to the inhibition of tumour angiogenesis, tumour growth and the development of metastasis was strongly reduced in SU5416 treated animals. This new approach enables non-invasive, repeated and quantitative assessment of tumour vascular network and the effects of antiangiogenic treatment on tumour vasculature in vivo. Thus, quantification of tumour angiogenesis can be used to more accurately classify and monitor tumour biologic characteristics, and to explore aggressiveness of tumours.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.