A new simple measurement system of visceral fat accumulation by bioelectrical impedance analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
56
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 39 publications
(59 citation statements)
references
References 5 publications
3
56
0
Order By: Relevance
“…Recently, a dual bioelectrical impedance analysis (Dual BIA) instrument that can determine IAFA by measuring truncal impedance and surface impedance at the abdomen separately, each of which reflects truncal and subcutaneous adiposity, respectively, has been developed [13][14][15][16]. The Dual BIA instrument has been optimized for robust use in a wide range of human variations by analyzing the size of the effect each parameter, such as age and gender, can have on the calculation's outcome by utilizing information technology [13][14][15][16]. The Dual BIA was able to detect weekly changes in IAFA under short-term calorie restriction in obese patients, and demonstrated a larger change of IAFA compared with changes of BW and WC [13].…”
Section: Data Collection and Laboratory Assay Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, a dual bioelectrical impedance analysis (Dual BIA) instrument that can determine IAFA by measuring truncal impedance and surface impedance at the abdomen separately, each of which reflects truncal and subcutaneous adiposity, respectively, has been developed [13][14][15][16]. The Dual BIA instrument has been optimized for robust use in a wide range of human variations by analyzing the size of the effect each parameter, such as age and gender, can have on the calculation's outcome by utilizing information technology [13][14][15][16]. The Dual BIA was able to detect weekly changes in IAFA under short-term calorie restriction in obese patients, and demonstrated a larger change of IAFA compared with changes of BW and WC [13].…”
Section: Data Collection and Laboratory Assay Methodsmentioning
confidence: 99%
“…Surface impedance is measured by applying and reading the voltage from the abdominal circumferential electrodes. The estimated IAFA by Dual BIA is calculated as follows [16]:…”
Section: Data Collection and Laboratory Assay Methodsmentioning
confidence: 99%
“…The principles of IAFA determination by the dual BIA instrument were described previously (Shiga, 2007(Shiga, , 2009Yoneda, 2007). Briefly, the dual BIA instrument consists of a bioelectric impedance component that measures the physical size of the abdomen.…”
Section: Dual Bia Methods and Instrumentationmentioning
confidence: 99%
“…www.intechopen.com Shiga et al proposed the model to estimate VFA, which employed two types of impedance and will be described in Section 3.1.2. The model is given by the equation (7) (Shiga, , 2009 …”
Section: Measurement Principlesmentioning
confidence: 99%
“…The model uses the only measured variables of waist circumference and the impedances. Some studies proposed the several models using the width and height of the cross sectional area of an abdomin (Shiga, 2009;. Some of them also employ other variables such as gender and age besides them .…”
Section:  mentioning
confidence: 99%