The method of bioelectrical impedance-based visceral fat estimation is in advance of other methods such as X-ray CT or MRI from the point views of cost and safety. However, it requires complex and diversity signal analysis and modeling to realize its high estimation accuracy. In response to this requirement, complication of feature attributes and simplification in selection of them to model the estimation has been proposed and evaluated in this paper. The complication of feature attributes is realized by applying priori knowledge and by employing the idea of cardinality as quantitative evaluation index. The simplification of the estimation model is realized by employing Akaike information criteria. The experiments were conducted to evaluate the proposed method and the results prove high estimation accuracy and stability of the proposed method.2007 IEEE International Conference on Granular Computing 0-7695-3032-X/07 $25.00
It has been clarified that abdominal visceral fat accumulation is closely associated to the lifestyle disease and metabolic syndrome. The gold standard in medical fields is visceral fat area measured by an X-ray computer tomography (CT) scan or magnetic resonance imaging. However, their measurements are high invasive and high cost; especially a CT scan causes X-ray exposure. They are the reasons why medical fields need an instrument for viscera fat measurement with low invasive, ease of use, and low cost. The article proposes a simple and practical method of visceral fat estimation by employing bioelectrical impedance analysis and causal analysis. In the method, abdominal shape and dual impedances of abdominal surface and body total are measured to estimate a visceral fat area based on the cause-effect structure. The structure is designed according to the nature of abdominal body composition to be fine-tuned by statistical analysis. The experiments were conducted to investigate the proposed model. 180 subjects were hired to be measured by both a CT scan and the proposed method. The acquired model explained the measurement principle well and the correlation coefficient is 0.88 with the CT scan measurements.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.