2017
DOI: 10.1016/j.jneumeth.2017.06.008
|View full text |Cite
|
Sign up to set email alerts
|

A non-invasive restraining system for awake mouse imaging

Abstract: Background Preclinical neuroimaging allows for the assessment of brain anatomy, connectivity and function in laboratory animals, such as mice and rats. Most of these studies are performed under anesthesia to avoid movement during the scanning sessions. Method Due to the limitations associated with anesthetized imaging, recent efforts have been made to conduct rodent imaging studies in awake animals, habituated to the restraint systems used in these instances. As of now, only one such system is commercially a… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
39
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 36 publications
(41 citation statements)
references
References 19 publications
(30 reference statements)
2
39
0
Order By: Relevance
“…We observed the similar skull stripping performance for T2 W (Dice = 0.97) and EPI (Dice = 0.96), indicating that the model is adequately trained and not susceptible to ghosting artifacts in EPI. Rodent EPI data is also less prone to motion because the subjects are either under anesthesia and secured with ear and tooth bars ( Atay et al, 2008 ; Albaugh et al, 2016 ; Van Den Berge et al, 2017 ; Broadwater et al, 2018 ; Grandjean et al, 2019 , 2020 ; Sirmpilatze et al, 2019 ; Mandino et al, 2020 ) or awake and tightly restrained ( Madularu et al, 2017 ; Ma et al, 2018 ). Indeed, none of the dataset available on online repository suffers from severe EPI ghosting.…”
Section: Discussionmentioning
confidence: 99%
“…We observed the similar skull stripping performance for T2 W (Dice = 0.97) and EPI (Dice = 0.96), indicating that the model is adequately trained and not susceptible to ghosting artifacts in EPI. Rodent EPI data is also less prone to motion because the subjects are either under anesthesia and secured with ear and tooth bars ( Atay et al, 2008 ; Albaugh et al, 2016 ; Van Den Berge et al, 2017 ; Broadwater et al, 2018 ; Grandjean et al, 2019 , 2020 ; Sirmpilatze et al, 2019 ; Mandino et al, 2020 ) or awake and tightly restrained ( Madularu et al, 2017 ; Ma et al, 2018 ). Indeed, none of the dataset available on online repository suffers from severe EPI ghosting.…”
Section: Discussionmentioning
confidence: 99%
“…Detailed description of the acclimation and imaging protocols can be found elsewhere (Madularu et al ., ,b, , ; Kenkel et al ., ). Briefly, prior to the first imaging session, all rats were acclimated to the imaging system environment before being placed into the scanner itself, over five consecutive days.…”
Section: Methodsmentioning
confidence: 99%
“…Briefly, prior to the first imaging session, all rats were acclimated to the imaging system environment before being placed into the scanner itself, over five consecutive days. Rats were secured into a mock holding system similar to the actual coil system (Animal Imaging Research, Holden, MA, USA) and placed into a mock scanner (a black box with a tape recording of MRI pulses) for 30 min at a time to reduce physiological effects of the scanner environment on the autonomic nervous system (King et al, 2005;Madularu et al, 2017). To deliver the test articles remotely, all animals in both groups had a piece of polyethylene tubing (PE-20) approximately 1 m in length positioned and secured prior to placement in the magnet with the tip placed for intraperitoneal (i.p.)…”
Section: Awake Imaging Protocolmentioning
confidence: 99%
“…These procedures often include a training period to acclimate animals to the scanning environment. Acclimation procedures have been utilized by a number of labs and have been shown on multiple occasions to diminish the motion and stress level of animals, measured by stress hormone levels, respiratory rate, heart rate and behavior ( Madularu et al, 2017 ; Schultz-Darken et al, 2004 ; Duyn, 2011 ; King et al, 2005 ; Ferenczi et al, 2016 ; Liang et al, 2014 ). These methods make it possible to image fully awake animals and allow for task-based designs to functionally map stress response in the brain, as well as a more accurate determination of resting-state functional networks related to stress processing in animals.…”
Section: Advantages Of Animal Fmri Studies Of Stressmentioning
confidence: 99%