A noninvasive heartbeat, respiration, and body movement monitoring system for neonates

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
27
0
1

Year Published

2015
2015
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 24 publications
(28 citation statements)
references
References 8 publications
0
27
0
1
Order By: Relevance
“…In adult patients, BCG showed almost the same results as classic PSG for sleep classification(62). The test on a preterm infant showed a very high correlation between an ECG Unobtrusive preterm sleep-state measurements 16 reference and a BCG of 0.91, and a BR reference and a BCG of 0.74, proving BCG to be a suitable alternative for detecting HR and BR in preterm infants(61). There are commercial products for infants using BCG, for example, AngelCare (www.angelcare.de) or NannyCare (www.nannycare.nl), but they are mostly used as sudden infant death syndrome alarm systems rather than continuous monitoring devices.BCG methods pose a difficulty in designing algorithms to separate HR and BR from motion and noise.…”
mentioning
confidence: 62%
See 1 more Smart Citation
“…In adult patients, BCG showed almost the same results as classic PSG for sleep classification(62). The test on a preterm infant showed a very high correlation between an ECG Unobtrusive preterm sleep-state measurements 16 reference and a BCG of 0.91, and a BR reference and a BCG of 0.74, proving BCG to be a suitable alternative for detecting HR and BR in preterm infants(61). There are commercial products for infants using BCG, for example, AngelCare (www.angelcare.de) or NannyCare (www.nannycare.nl), but they are mostly used as sudden infant death syndrome alarm systems rather than continuous monitoring devices.BCG methods pose a difficulty in designing algorithms to separate HR and BR from motion and noise.…”
mentioning
confidence: 62%
“…and even tested in the NICU(61). In adult patients, BCG showed almost the same results as classic PSG for sleep classification(62).…”
mentioning
confidence: 89%
“…After inclusion of four additional studies identified through references and citation of eligible studies , 15 articles were identified for analysis in this review .…”
Section: Resultsmentioning
confidence: 99%
“…The technologies assessed by these studies were camera‐based photoplethysmography , reflectance PO , laser Doppler methods , capacitive sensors , piezoelectric sensors , transcutaneous electromyography , and a digital stethoscope . Appendix contains brief, plain‐language descriptions of these technologies.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation