2018
DOI: 10.1039/c8ra04596h
|View full text |Cite
|
Sign up to set email alerts
|

A novel biosensor based on ball-flower-like Cu-hemin MOF grown on elastic carbon foam for trichlorfon detection

Abstract: The Cu-hemin MOFs/nitrogen-doped elastic carbon foam (Cu-hemin MOFs/NECF) composite structure was constructed as the supporting matrix to load acetylcholinesterase (AChE) for preparing pesticide biosensors.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
5
0
3

Year Published

2019
2019
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(9 citation statements)
references
References 44 publications
(31 reference statements)
1
5
0
3
Order By: Relevance
“…Their diameters were estimated to be about 2.5 mm which is much smaller than previously reported. 5,34 At the same time, it could be seen from Fig. 1B and C that the material also had ultra-thin lamellar structure.…”
Section: Resultsmentioning
confidence: 66%
“…Their diameters were estimated to be about 2.5 mm which is much smaller than previously reported. 5,34 At the same time, it could be seen from Fig. 1B and C that the material also had ultra-thin lamellar structure.…”
Section: Resultsmentioning
confidence: 66%
“…Su et al. synthesized Cu‐H MOFs/NECF composites consisting of ball‐flower‐like Cu‐hemin MOFs grown on the fibers of 3D nitrogen‐containing melamine carbon foam (NECF) and immobilized AChE on Cu‐H MOFs/NEC for trichlorfon detection [96] . The Cu‐H MOFs/NECF‐based biosensor exhibited great performance for trichlorfon detection with a broad linear range (0.25–20 ng mL −1 ), low detection limit (0.082 ng mL −1 ), and good stability, and thereby facilitated trace detection of organophosphorus pesticides.…”
Section: Biomedical Applications Of Porphyrin‐based Mofsmentioning
confidence: 99%
“…Aufd iesen Kompositen wurde fürd ie Trichlorfon-Erkennung AChE immobilisiert. [96] Die Detektion konnte in einem großen linearen Bereich (0.25-20 ng mL À1 ) mit niedriger Nachweisgrenze (0.082 ng mL À1 )d urchgeführt werden. Außerdem weist der Biosensor eine gute Stabilität auf,w odurch die Spurenanalytik von Organophosphatpestiziden vereinfacht wird.…”
Section: Aufsätzeunclassified
“…Aufd iesen Kompositen wurde fürd ie Trichlorfon-Erkennung AChE immobilisiert. [96] [100] Auch wenn sich die Sensorik von Anionen als anspruchsvoller gestaltet, gibt es hierfüre inige Beispiele Porphyrin-basierter MOFs.C ao et al entwickelten ein Zr-basiertes MOF mit zwei Linkern, nämlich 1,3,6,8-Tetra(4-carboxyphenyl)pyren (TBAPy) und TCPP (Zr(TBAPy) 5 (TCPP)) als Tu rn-on-Fluoreszenzbiosensorf ürd ie Detektion von S 2À im wässrigen Milieu. [36c] Die Ergebnisse zeigten, dass das Fluoreszenzsignal nach der Zugabe von S 2À -Ionen deutlich gesteigert werden konnte,w obei Ionen wie SO 4 2À ,C NS À , COOH À ,B r À ,I À ,I O 3 À ,F À ,H SO 3 À ,C l À und NO 3 À keine Signalveränderung auslçsten.…”
Section: Aufsätzeunclassified