1987
DOI: 10.1016/0022-1759(87)90454-6
|View full text |Cite
|
Sign up to set email alerts
|

A novel coloured latex test for the detection and identification of more than one antigen

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
11
0

Year Published

1988
1988
2016
2016

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 35 publications
(11 citation statements)
references
References 4 publications
0
11
0
Order By: Relevance
“…Such assays can take up to five days to perform (Anon, 1978). Antibody technology is now beginning to make an impact in microbiological areas, and several immunoassays for Salmonella have been described (Krysinski & Heimsch, 1977;Mattingly, 1984;Ibrahim et ai, 1986;Hadfield et al, 1987) which are available commercially as kits. One of the kits has been declared official first-action by the Association of Official Analytical Chemists (Flowers et al, 1986).…”
Section: Introductionmentioning
confidence: 99%
“…Such assays can take up to five days to perform (Anon, 1978). Antibody technology is now beginning to make an impact in microbiological areas, and several immunoassays for Salmonella have been described (Krysinski & Heimsch, 1977;Mattingly, 1984;Ibrahim et ai, 1986;Hadfield et al, 1987) which are available commercially as kits. One of the kits has been declared official first-action by the Association of Official Analytical Chemists (Flowers et al, 1986).…”
Section: Introductionmentioning
confidence: 99%
“…To this end, researchers have used antibodies or antigens in the same assay zone labeled with (a) different fluorescent molecules (6,7), (b) different radioactive species (8 -10), (c) different enzymes (11,12), (d) a mixture of radioactive species and enzymes (13), (e) metal ions (14), (f) colored latex particles (15), and (g) particles of different sizes (16). The various detection schemes used in these multianalyte assays are based on a change in one or more of the following signals: absorbance, steady-state fluorescence, fluorescence lifetime, chemiluminescence, radioactivity, electrochemical response, laser light scattering, and frequency of apiezoelectric quartz crystal, upon the binding event(s) (6 -20).…”
mentioning
confidence: 99%
“…These include the Oxoid Salmonella Latex Kit (Oxoid, Basingstoke, UK) designed to be used with the Oxoid Rapid Salmonella Test Kit (Holbrook et al, 1989); the Microscreen Salmonella Latex Slide Agglutination Test (Mercia Diagnostics Ltd, UK); the Wellcolex ® Colour Salmonella Test (Remel Inc, USA) (Hadfield et al, 1987a, b); and the Spectate ® Salmonella test (Rhône Poulenc Diagnostics Ltd, UK) (Clark et al, 1989). The latter two kits use mixtures of coloured latex particles that allow not only detection but also serogrouping of Salmonella.…”
Section: Labelsmentioning
confidence: 99%