A novel grid impedance estimation technique based on adaptive virtual resistance control loop applied to distributed generation inverters

Abstract: The penetration of the distributed power generation systems (DPGSs) based on renewable sources (PV, WT) is strongly dependent on the quality of the power injected to the utility grid. However, the grid impedance variation, mainly caused by grid faults somewhere in the electric network, can degrade the power quality and even damage some sensitive loads connected at the point of the common coupling (PCC). This paper presents detection-estimation method of the grid impedance variation. This estimation tehnique ai… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2014
2014
2017
2017

Publication Types

Select...
3
2
1

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(6 citation statements)
references
References 18 publications
0
6
0
Order By: Relevance
“…for the lowest possible value of the load power, then it is valid for all other loads. Eventhough this scheme does not require knowledge of source impedance throughout the DSTATCOM operation, several schemes for online grid impedance measurement have been available [23]- [27].…”
Section: B Control Of DC Link Voltagementioning
confidence: 99%
“…for the lowest possible value of the load power, then it is valid for all other loads. Eventhough this scheme does not require knowledge of source impedance throughout the DSTATCOM operation, several schemes for online grid impedance measurement have been available [23]- [27].…”
Section: B Control Of DC Link Voltagementioning
confidence: 99%
“…For this reason, active damping is adopted as a solution and it is carried out by implementing a virtual resistance in the control strategy. In fact, it is done by multiplying the sensed filtercapacitor current by a predetermined gain noted R v [3], and the result of this multiplication is subtracted from the converter voltage reference as depicted in Fig. 3.…”
Section: Non-controllable Dgs Strategymentioning
confidence: 99%
“…However, unplanned islanding, that is to say the failure of the grid, is more complicated to be detected since the voltage and frequency at PCC can be sustained in NDZ limits. In the literature, several methods have been proposed for islanding detection due to the importance of this issue and its impact on the interconnected system behavior [19,1,14,3,8,6]. These methods are mainly divided into two main categories: communication-based methods between the protection devices and the power generation system, and local methods that use only local measurements.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Moreover, some tests use the frequency analyzer devices to obtain the impedance in the frequency domain [14]. Additionaly, some estimation techniques, in this case for grid impedance equivalent, have been presented in [15], [16]. Reference [12] stated that the use of sinusoidal current/voltage sweeps to compute the impedance is the most reliable and accurate method and that this is not suited for online measurements due to the measurement time.…”
Section: Introductionmentioning