2020
DOI: 10.1039/d0ay01592j
|View full text |Cite
|
Sign up to set email alerts
|

A novel hybrid fluorescence probe sensor based on metal–organic framework@carbon quantum dots for the highly selective detection of 6-mercaptopurine

Abstract: In this present study, MIL-101(Fe) and amine-carbon quantum dots (CQDs) were combined by means of a post-synthetic modification (PSM) method, thus a novel MIL-101(Fe)@amine-CQDs hybrid fluorescent probe sensor for detection...

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
17
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

3
5

Authors

Journals

citations
Cited by 45 publications
(17 citation statements)
references
References 50 publications
0
17
0
Order By: Relevance
“…6-Mercaptopurine (6-MP) is one of the anticancer drugs used to treat acute lymphocytic leukemia, a type of cancer of the blood and bone marrow. Acute lymphocytic leukemia is one of the most common cancers in children. ,, Nevertheless, its medical use has been limited by side effects such as oligospermia, renal toxicity, bone marrow suppression, granulocytopenia, and lymphocytopenia . More effective treatment should be used to reduce the side effects and improve the efficacy. , For this reason, the use of smart medicine is now being considered.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…6-Mercaptopurine (6-MP) is one of the anticancer drugs used to treat acute lymphocytic leukemia, a type of cancer of the blood and bone marrow. Acute lymphocytic leukemia is one of the most common cancers in children. ,, Nevertheless, its medical use has been limited by side effects such as oligospermia, renal toxicity, bone marrow suppression, granulocytopenia, and lymphocytopenia . More effective treatment should be used to reduce the side effects and improve the efficacy. , For this reason, the use of smart medicine is now being considered.…”
Section: Introductionmentioning
confidence: 99%
“…Acute lymphocytic leukemia is one of the most common cancers in children. 4,24,25 Nevertheless, its medical use has been limited by side effects such as oligospermia, renal toxicity, bone marrow suppression, granulocytopenia, and lymphocytopenia. 26 More effective treatment should be used to reduce the side effects and improve the efficacy.…”
Section: Introductionmentioning
confidence: 99%
“…Shuang’s group designed an anthraquinone–imidazole-based colorimetric and fluorescent sensor for the analysis of Ag­(I) and thiols . Zare-Dorabei’s groups synthesized diphenylthiocarbazone immobilized on the triacetyl cellulose membrane, a nanocomposite containing silver sulfide QDs and graphitic carbon nitride nanosheets (g-C 3 N 4 NNs), and a series of nanomaterials to detect Ag­(I), small biological molecules, and other hazardous substances. Liao’s group prepared the g-C 3 N 4 NNs/polyacrylamide/polyacrylic acid composite hydrogel by using the radical polymerization method, which can act as a fluorescent probe to detect Ag­(I) with a limit of detection (LOD) of 6.31 μmol L –1 . Chen’s group synthesized the acetaldehyde-modified g-C 3 N 4 NNs through the ethylene glycol-assisted liquid exfoliation method, which was successfully used to detect Ag­(I) based on the photo-induced electron transfer (PET) .…”
Section: Introductionmentioning
confidence: 99%
“…In this phenomenon, Cr(III) would absorb the emission light of S-CDs, but the excitation light would be constant since the addition of Cr(III) into the S-CDs solution. Therefore, the emission PL intensity of S-CDSs would be a turn-off (Shahbazi and Zare-Dorabei 2019;Mousavi et al 2020). Figure 6b shows no difference in absorption spectrum S-CDs both in absence Cr(III) and presence Cr(III).…”
Section: Possible Mechanism Of Cr(iii) Detectionmentioning
confidence: 93%