2010
DOI: 10.1016/j.snb.2010.03.034
|View full text |Cite
|
Sign up to set email alerts
|

A novel methyl parathion electrochemical sensor based on acetylene black–chitosan composite film modified electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0
1

Year Published

2012
2012
2021
2021

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 43 publications
(3 citation statements)
references
References 30 publications
0
2
0
1
Order By: Relevance
“…AB is a carbon nanomaterial which is a specific subtype of carbon black and is produced by the controlled combustion of acetylene under pressurized air. ABs are usually used as substitutes for graphitic powder in the preparation of carbon paste electrodes, and are dispersed in chitosan solution to modify glassy carbon electrodes . An acetylene black–dihexadecyl hydrogen phosphate (AB–DHP) film-coated glassy carbon electrode (GCE) was also constructed to detect 2-chlorophenol and erythromycin …”
Section: Conjugated π Conductive Polymersmentioning
confidence: 92%
See 1 more Smart Citation
“…AB is a carbon nanomaterial which is a specific subtype of carbon black and is produced by the controlled combustion of acetylene under pressurized air. ABs are usually used as substitutes for graphitic powder in the preparation of carbon paste electrodes, and are dispersed in chitosan solution to modify glassy carbon electrodes . An acetylene black–dihexadecyl hydrogen phosphate (AB–DHP) film-coated glassy carbon electrode (GCE) was also constructed to detect 2-chlorophenol and erythromycin …”
Section: Conjugated π Conductive Polymersmentioning
confidence: 92%
“…ABs are usually used as substitutes for graphitic powder in the preparation of carbon paste electrodes, 24−26 and are dispersed in chitosan solution to modify glassy carbon electrodes. 27 An acetylene black− dihexadecyl hydrogen phosphate (AB−DHP) film-coated glassy carbon electrode (GCE) was also constructed to detect 2-chlorophenol 28 and erythromycin. 21 With the physical inclusion of enzymes, quaternized cellulose NPs (QCs)/acetylene black (AB)/enzyme composite electrodes have been constructed in the electrode matrix bulk.…”
Section: Introductionmentioning
confidence: 99%
“…6, HSA NP/p(CTAB)/PGE ile pH 4,0 BRT'de tarama hızının MP'nin pik akımı (Ip) üzerindeki etkisini incelemek için 10-200 mVs −1 aralığında kaydedilen voltammogramları göstermektedir. Katodik pik akımlarının, tarama hızı ile doğrusal olarak artması, MP'nin indirgenme kinetiğinin adsorpsiyon kontrollü davranış gösterdiği şeklinde yorumlandı[39]. Ayrıca, artan tarama hızıyla pik potansiyellerindeki kayma, indirgenme reaksiyonunun tersinmez olduğunu gösterdi.…”
unclassified