2016
DOI: 10.1063/1.4966680
|View full text |Cite
|
Sign up to set email alerts
|

A novel multi-channel quadrature Doppler backward scattering reflectometer on the HL-2A tokamak

Abstract: A novel 16-channel fixed frequency Doppler backward scattering (DBS) reflectometer system has been developed on the HL-2A tokamak. This system is based on the filter-based feedback loop microwave source (FFLMS) technique, which has lower phase noise and lower power variation compared with present tunable frequency generation and comb frequency array generation techniques [J. C. Hillesheim et al. Rev. Sci. Instrum. 80, 083507 (2009) and W. A. Peebles et al. Rev. Sci. Instrum. 81, 10D902 (2010)]. The 16-channel … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
33
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 50 publications
(33 citation statements)
references
References 25 publications
0
33
0
Order By: Relevance
“…Three frequency modulation continuous wave (FMCW) reflectometers and two amplitude modulation (AM) reflectometers are developed to measure the density profiles from low field side in the horizontal plane [31][32][33][34]. Two sweeping DBS reflectometers and four by four fixed-frequency DBS reflectometers are developed to measure the profiles of the plasma rotation and turbulence [15,35,36].…”
Section: Overview Of Microwave Diagnostics On Hl-2amentioning
confidence: 99%
See 2 more Smart Citations
“…Three frequency modulation continuous wave (FMCW) reflectometers and two amplitude modulation (AM) reflectometers are developed to measure the density profiles from low field side in the horizontal plane [31][32][33][34]. Two sweeping DBS reflectometers and four by four fixed-frequency DBS reflectometers are developed to measure the profiles of the plasma rotation and turbulence [15,35,36].…”
Section: Overview Of Microwave Diagnostics On Hl-2amentioning
confidence: 99%
“…The multiple-simultaneouschannel DBS system provides significant flexibility for experimental observations, especially for the fast variation phenomena, like L-H transition, ELMs and nonlinear interaction of turbulence. To measure the density fluctuation and poloidal rotation profile simultaneously, four four-frequency (16-fixed frequencies) DBS systems have been developed on the HL-2A tokamak [15]. The unique feature of the multichannel DBS system is the development of the filter-based feedback loop microwave source (FFLMS) technique.…”
Section: Doppler Backward Scattering Reflectometermentioning
confidence: 99%
See 1 more Smart Citation
“…Doppler backscattering (DBS) diagnostic. For DBS, a tilt angle of the microwave beam is launched relative to the normal of the cutoff layer and backscattered radiation is detected [14,15]. The CPS diagnostic was originally demonstrated on Tore Supra tokamak [16], where the effect of magnetic fluctuations on electron heat transport was studied.…”
Section: Introductionmentioning
confidence: 99%
“…Here, k ⊥ is the wavenumber of turbulent fluctuations perpendicular to the magnetic field, and ρ i is the ion gyroradius. Consequently, it is a widely used diagnostic for both tokamaks and stellarators [8,9,10,11,12,13,14,15,16,17,18]. Moreover, since DBS is a microwave diagnostic, it is one of the few diagnostics that can be used in burning plasma because they are resilient to high neutron fluxes [19,20].…”
Section: Introductionmentioning
confidence: 99%