A Novel Physiologically Based Algorithm (PBA) for Fast CFD Computation of Flow Fractional Reserve (FFR) in Coronary Artery Trees

Abstract: A novel physiologically based algorithm (PBA) for fast CFD computation of Flow Fractional Reserve (FFR) in Coronary Artery Trees (CATs) is proposed and developed, which, unlike traditional methods, is based on the extension of the Murray’s law for blood vessels at the outlets and extra inlet conditions prescribed alternatively and iteratively. The PBA is then implemented in both SimVascular and Ansys CFD for testing and validation. For validation purpose, 3D models of CATs are built by using their CT… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

1
7
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(8 citation statements)
references
References 12 publications
1
7
0
Order By: Relevance
“…The calculated noninvasive FFR value of 0.73 by Zhang et al [ 23 ] is different from the experimental (ICA) FFR value of approximately 0.76 for the CT209 model. After conducting a mesh sensitivity analysis, Sumbekova et al [ 19 ] from our research group obtained a final FFR value of FFR = 0.757, which was very close to the ICA FFR. The same algorithm implemented in OpenFOAM produced results that were similar to the ICA measurement, with a final FFR value of FFR = 0.762.…”
Section: Resultssupporting
confidence: 58%
See 4 more Smart Citations
“…The calculated noninvasive FFR value of 0.73 by Zhang et al [ 23 ] is different from the experimental (ICA) FFR value of approximately 0.76 for the CT209 model. After conducting a mesh sensitivity analysis, Sumbekova et al [ 19 ] from our research group obtained a final FFR value of FFR = 0.757, which was very close to the ICA FFR. The same algorithm implemented in OpenFOAM produced results that were similar to the ICA measurement, with a final FFR value of FFR = 0.762.…”
Section: Resultssupporting
confidence: 58%
“…cfMesh is also able to automatically generate tetrahedral meshes for a variety of geometries, as shown in Figure 9 . A mesh sensitivity analysis was conducted [ 19 ], and the same models were used in this study. For the CT209, CHN13, and CHN03 arteries, our research group [ 19 ] calculated mesh sizes and numbers of grid cells based on the results of the mesh sensitivity analysis.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations